Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NEWLAND CONSTRUCTION, LLC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of NEWLAND CONSTRUCTION, LLC in 3609 BREWERTON ROAD, NORTH SYRACUSE, NY 13212 (NAICS 236220). OSHA activity number 340650811.

Watch Newland Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Newland Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3609 BREWERTON ROAD
City
NORTH SYRACUSE
State
NY
ZIP
13212
Mailing
561 HILL STREET, YORK, PA 17403
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.451 B01 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.      a) At the establishment, on or about 5/22/2015: An employee worked from the top tier of a scaffold which was not fully planked, leaving a space between the partial plank and the upright of approximately 10 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.451 E01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, stairway-type ladders, ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used for access:      a) At the establishment, on or about 5/22/2015: An employee climbed to the top tier/working surface of a scaffold without safe access.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F03

Deleted Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:      a) At the establishment, or or about 5/22/2015: An employee utilized an improperly erected scaffold, with the following unsafe conditions: no guardrails on the top tier, not fully planked, and without safe access.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.451 F07

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person.      a) At the establishment, on or about 5/22/2015: Scaffolds were not erected, moved, altered or used by or under the supervision of an experienced, trained or competent person in scaffolds.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.      a) At the establishment, on or about 5/22/2015: An employee working on a scaffold approximately 14 feet above the concrete ground was not protected from falling as required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.451 G04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.      a) At the establishment, on or about 5/22/2015: Guardrail systems were not installed as required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 B

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question:      a) At the establishment, on or about 5/22/2015: Employees erecting, moving, maintaining or inspecting a supported      mobile scaffold system were not trained by a person knowledgeable in scaffold requirements.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340650811.