CAMPBELL HALL, NY —
OSHA Inspection: MCNEILLY WOOD PRODUCTS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MCNEILLY WOOD PRODUCTS INC. in 120 NEELEYTOWN ROAD, CAMPBELL HALL, NY 10916 (NAICS 321920). OSHA activity number 340652171.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCNEILLY WOOD PRODUCTS INC.
- Site address
- 120 NEELEYTOWN ROAD
- City
- CAMPBELL HALL
- State
- NY
- ZIP
- 10916
- Mailing
- 120 NEELEYTOWN ROAD, CAMPBELL HALL, NY 10916
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 45
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Sep 29, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $5,390 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Brewer re-saw- On or about 5/15/2015, employees were exposed to amputation hazards while reaching into the saw to free a jammed cant beam without utilizing the Lock-Out / Tag-Out procedure.
Recent events (2)
- — I (S) $4500
- — Z (S) $5390
1910.147 D04 I
- Issued
- Sep 29, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Brewer Re-saw- On or about 5/15/2015, employees were exposed to moving blades while removing a jam in the machine. A lockout device was not affixed to the power sources prior to servicing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C05 II D
- Issued
- Sep 29, 2015
- Abate by
- Oct 7, 2015
- Penalty
- Initial $578 · Current $500 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the devices; a) 480 Volt Panel behind the Brewer re-saw- On or about 5/21/2015, Lockout devices affixed to the panel did not identify both employees who locked out the equipment.
Recent events (2)
- — I (O) $500
- — Z (O) $578
More inspections at Mcneilly Wood Products INC.
View Mcneilly Wood Products INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340652171.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.