HOUSTON, TX —
OSHA Inspection: SAMUEL LOPEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SAMUEL LOPEZ in 11503-11515 ROYAL IVORY CROSSING, HOUSTON, TX 77082 (NAICS 238140). OSHA activity number 340656529.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMUEL LOPEZ
- Site address
- 11503-11515 ROYAL IVORY CROSSING
- City
- HOUSTON
- State
- TX
- ZIP
- 77082
- Mailing
- 1300 REDFORD ST., HOUSTON, TX 77034
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Aug 4, 2015
- Abate by
- Aug 8, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch wide: a) On the east side of the building, where a tubular welded frame scaffold was not fully planked on the second level tier. Employees were applying tape flashing from this level.
Recent events (1)
- — Z (S) $1600
1926.451 C01 II
- Issued
- Aug 4, 2015
- Abate by
- Aug 8, 2015
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide: a) On the east side of the building, where a 3-foot wide tubular welded frame scaffold was not restrained from tipping at 12 feet.
Recent events (1)
- — Z (S) $2400
1926.451 C02
- Issued
- Aug 4, 2015
- Abate by
- Aug 8, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) At the worksite, a 3 foot wide tubular welded scaffolding system was not supported by adequate base plates and/or mud sills.
Recent events (1)
- — Z (S) $1600
1926.451 E01
- Issued
- Aug 4, 2015
- Abate by
- Aug 8, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: a) At the worksite, a 3-foot wide, 2-tier high tubular welded scaffolding system was not provided with a safe means of accessing platforms.
Recent events (1)
- — Z (S) $1600
1926.451 F07
- Issued
- Aug 4, 2015
- Abate by
- Sep 6, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) At the worksite, where the designated competent person overseeing the erection and alteration of a tubular welded frame scaffold was not competent in that he did not know the OSHA requirements for scaffolds.
Recent events (1)
- — Z (S) $2000
1926.451 G04 I
- Issued
- Aug 4, 2015
- Abate by
- Aug 8, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) At the worksite where a tubular welded scaffolding system had unprotected sides and ends due to the lack of guardrails.
Recent events (1)
- — Z (S) $2000
More inspections at Samuel Lopez
View Samuel Lopez's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340656529.