LA CROSSE, WI —
OSHA Inspection: COMPLETE AUTO-MATION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMPLETE AUTO-MATION, INC. in 2340 ENTERPRISE AVE., LA CROSSE, WI 54602 (NAICS 238290). OSHA activity number 340660190.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMPLETE AUTO-MATION, INC.
- Site address
- 2340 ENTERPRISE AVE.
- City
- LA CROSSE
- State
- WI
- ZIP
- 54602
- Mailing
- P.O. BOX 65, LAKE ORION, MI 48361
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238290
- Employees
- 30
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 4, 2015
- Abate by
- Dec 11, 2015
- Penalty
- Initial $5,100 · Current $3,060 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section: On or about May 14, 2015, energy control procedures were not utilized for the control of pressurized air during set-up operations involving the CIP connection for the #2 vacuum receiver return line.
Recent events (2)
- — I (S) $3060
- — Z (S) $5100
1910.147 D03
- Issued
- Nov 4, 2015
- Abate by
- Dec 11, 2015
- Penalty
- Initial $5,100 · Current $3,060 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment were not operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about May 14, 2015, energy isolating devices were not operated so as to isolate pressurized air from the CIP line for the vacuum receiver #2.
Recent events (2)
- — I (S) $3060
- — Z (S) $5100
1910.147 D04 I
- Issued
- Nov 4, 2015
- Abate by
- Nov 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about May 14, 2015, lockout or tagout devices were not affixed to each energy isolating device for pressurized air on the CIP line for vacuum receiver #2.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D06
- Issued
- Nov 4, 2015
- Abate by
- Nov 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that have been locked out or tagged out, an authorized employee did not verify that isolation and de-energization of the machine or equipment had been accomplished: On or about May 14, 2015, the de-energization of air pressure was not verified during set up work for the CIP return line on the #2 vacuum receiver.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Complete Auto-Mation, INC.
View Complete Auto-Mation, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238290)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340660190.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.