OSHKOSH, WI —
OSHA Inspection: MUZA METAL PRODUCTS, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MUZA METAL PRODUCTS, LLC in 606 E. MURDOCK AVE., OSHKOSH, WI 54903 (NAICS 332116). OSHA activity number 340661669.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MUZA METAL PRODUCTS, LLC
- Site address
- 606 E. MURDOCK AVE.
- City
- OSHKOSH
- State
- WI
- ZIP
- 54903
- Mailing
- 606 E MURDOCK AVE, OSHKOSH, WI 54903
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 270
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.134 H04 I
- Issued
- Aug 19, 2015
- Abate by
- Sep 10, 2015
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.134(h)(4)(i): Repairs or adjustments to respirators were not made using the respirator manufacturer's NIOSH-approved parts designed for that respirator: a) The 3M L-901 SG air supplied helmet respirators used by the Powder Coaters had duct tape applied to the visors to eliminate leakage.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.1000 A02
- Issued
- Aug 19, 2015
- Abate by
- Feb 1, 2017
- Penalty
- Initial $3,400 · Current $2,040 Reduced
9135
General-duty citation text
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of particulates not otherwise regulated (PNOR) total dust listed in Table Z-1 in excess of the 8 hour Time Weighted Average (TWA) concentration of 15 mg/M3: a) In the Powder Coat area, a Painter employee was exposed to airborne PNOR at a level of 21 mg/M3 as an 8-hour TWA on May 28, 2015, approximately 1.4 times the PEL of 15 mg/M3. This exposure was determined by air sampling over 404 minutes during one shift, with zero exposure being assumed for the unsampled 76 minutes of an 8-hour work shift.
Recent events (2)
- — I (S) $2040
- — Z (S) $3400
1910.1000 E
- Issued
- Aug 19, 2015
- Abate by
- Feb 1, 2017
- Penalty
- Initial $0 · Current $0
9135
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): a) In the Powder Coat area, a Painter employee was exposed to airborne PNOR at a level of 21 mg/M3 as an 8-hour TWA on May 28, 2015, approximately 1.4 times the PEL of 15 mg/M3. This exposure was determined by air sampling over 404 minutes during one shift, with zero exposure being assumed for the unsampled 76 minutes of an 8-hour work shift. Applicable administrative controls or engineering controls may include, but are not limited to, the following: 1) While spraying, position the Powder Coaters so that they are not in the air stream carrying excess powder coat into the dust collection system. 2) During powder booth clean ups, minimize the usage of airborne dust generation techniques, such as, sweeping and compressed air. Usage of a vacuum system, approved for collection of potential combustible dust, can reduce the air borne dust generated during powder booth clean ups. 3) Redesign the powder coat booth so Powder Coaters spray through an booth opening with the dust collection air flow going into the booth. The powder coating application wands/guns may need to be expended to reach the parts. 4) Conduct personal air monitoring to ensure implemented engineering and/or administrative controls are effective at reducing exposures below the applicable PEL.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Muza Metal Products, LLC