ELLENVILLE, NY —
OSHA Inspection: GABY'S CAFE CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GABY'S CAFE CORP. in 141 CANAL STREET, ELLENVILLE, NY 12428 (NAICS 238350). OSHA activity number 340661800.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GABY'S CAFE CORP.
- Site address
- 141 CANAL STREET
- City
- ELLENVILLE
- State
- NY
- ZIP
- 12428
- Mailing
- 14 SANDRA STREET, ELLENVILLE, NY 12428
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.304 F
- Issued
- Jul 1, 2015
- Penalty
- Initial $1,600 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.304(f): All woodworking tools and machinery did not meet the applicable requirements of ANSI 01.1 - 1961 Safety Code for Woodworking Machinery: (a) Front of the Building - on or about May 14, 2015 - the Ridgid portable table saw, model# TS2400-1, serial# V043545729, was not equipped with a magnetic anti-restart switch. Section 3.1.3(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery, as adopted by 29 CFR 1926.304(f): On applications where injury to the operator might result if motors were to restart after power failures, provisions shall be made to prevent machines from automatically restarting upon restoration of power. (b) Front of the Building - on or about May 14, 2015 - the Ridgid portable table saw, model# TS2400-1, serial# V043514729, was not equipped with a material spreader. Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back at the operator: (c) Front of the Building - on or about May 14, 2015 - the Ridgid portable table saw, model# TS2400-1, serial# V043514729, was not equipped with non-kick back dogs. Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with non-kickback dogs or fingers so located as to oppose the thrust or tendency of the saw to pick up the material or throw it back toward the operator.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
1926.304 I01
- Issued
- Jul 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1): Each circular hand-fed rip saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: (a) Front of the Building - on or about May 14, 2015 - the Ridgid portable table saw, model# TS2400-1, serial# V043545729, was not equipped with a hood guard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Jul 1, 2015
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: (a) Front of the Building - on or about May 28, 2015 - the two scaffold systems were not erected by a scaffold competent person.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.1053 B01
- Issued
- Jul 1, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Front of the Building - on or about May 28, 2015 - the access ladder for the scaffold system did not extend the requisite three-feet above the upper surface.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.404 A02
- Issued
- Jul 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(a)(2): A grounded conductor was attached to a terminal or lead so as to reverse designated polarity: (a) Rear of the Building - on or about May 28, 2015 - the DeWalt portable hand grinder, model# D28402, serial# 6153206, was plugged into an extension cord that was wired in reverse polarity.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.404 F06
- Issued
- Jul 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) Rear of the Building - on or about May 28, 2015 - the DeWalt portable hand grinder, model# D28402, serial# 6153206, was plugged into an extension cord that was not provided with a grounding conductor.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.416 E01
- Issued
- Jul 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) Rear of the Building - on or about May 28, 2015 - the DeWalt portable hand grinder, model# D28402, serial# 6153206, was plugged into an extension cord that had extensive outer jacket insulation damage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.451 C02 I
- Issued
- Jul 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: (a) Front of the Building - on or about May 28, 2015 - the two scaffold systems were not set on leveling base plates, and were erected and used out of level.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238350)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340661800.