Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KICKHAEFER MANUFACTURING COMPANY, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KICKHAEFER MANUFACTURING COMPANY, LLC in 1221 SOUTH PARK STREET, PORT WASHINGTON, WI 53074 (NAICS 332999). OSHA activity number 340663426.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kickhaefer Manufacturing Company, LLC — free Get an email when a new federal OSHA severe-injury report for Kickhaefer Manufacturing Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1221 SOUTH PARK STREET
City
PORT WASHINGTON
State
WI
ZIP
53074
Mailing
PO BOX 348, PORT WASHINGTON, WI 53074
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
150
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2015
Abate by
Nov 19, 2015
Penalty
Initial $3,740 · Current $1,870 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    (a) The machine specific procedures did not clearly and specifically outline the techniques to be utilized for the control of hazardous energy for machinery in the facility including but not limited to: the thermal energy in the heating elements of the Stoelting Conveyorized Parts Washer.
Recent events (2)
  • — I (S) $1870
  • — Z (S) $3740

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 13, 2015
Abate by
Dec 10, 2015
Penalty
Initial $4,675 · Current $2,338 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) The employer did not ensure that the ingoing nip point created by the metal belt and cylinder at the front of the Stoelting Conveyorized parts Washer was guarded.
Recent events (2)
  • — I (S) $2337.5
  • — Z (S) $4675

1910.147 C06 I C

Other-than-serious 1 instance 1 exposed
Issued
Nov 13, 2015
Abate by
Dec 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.  (a) Authorized employees are not receiving periodic review between them and an instructor on their responsibilities under the energy control procedures they utilize.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Kickhaefer Manufacturing Company, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340663426.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.