Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PFINISH KONCEPTS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of PFINISH KONCEPTS, INC. in GIFT SHOP RENOVATION PROJECT AT HARRAH'S RESORT SOUTHERN CALIFORNIA 777 HARRAHS RINCON WAY, RINCON BAND OF LUESENO INDIANS TRIBAL LAND, VALLEY CENTER, CA 92082 (NAICS 238330). OSHA activity number 340669407.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pfinish Koncepts, INC. — free Get an email when a new federal OSHA severe-injury report for Pfinish Koncepts, INC. is published. One employer, no account, unsubscribe in one click.
Site address
GIFT SHOP RENOVATION PROJECT AT HARRAH'S RESORT SOUTHERN CALIFORNIA 777 HARRAHS RINCON WAY, RINCON BAND OF LUESENO INDIANS TRIBAL LAND
City
VALLEY CENTER
State
CA
ZIP
92082
Mailing
2820 N. SAN FERNANDO BLVD., BURBANK, CA 91504
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238330
Employees
70
Ownership type
A

3 citations on file for this inspection.

1910.1200 H01

Deleted Serious Gravity 1 1 instance 6 exposed
Issued
Jun 23, 2015
Abate by
Jul 1, 2015
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.1200(h)(1) referenced by 29 CFR 1926.59: The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about was introduced into their work area:  At the project, employees were not provided with effective information and training as employees said Laticrete Hydro Ban sealant was not hazardous despite being a chemical recognized by the state of California to cause cancer.  In addition, the foreman said he was trained on the hazards of the chemical about 15 years ago while the date on the onsite material safety data sheet was 01/25/2007.  Employees that applied the sealant with paint rollers and sponges and with sealant on their hands were exposed to the hazards of contacting a chemical recognized by the state of California to cause cancer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1785

1926.95 A

Other-than-serious 1 instance 6 exposed
Issued
Jun 23, 2015
Abate by
Jul 1, 2015
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    At the project, gloves were not worn while applying with sponges and paint rollers Laticrete Hydro Ban sealant on the concrete floor.  Employees with sealant on their hands were exposed to the hazards of contacting a chemical recognized by the state of California to cause cancer.
Recent events (2)
  • — I (O) $893
  • — Z (S) $1785

1926.417 B

Deleted Serious Gravity 1 1 instance 6 exposed
Issued
Jun 23, 2015
Abate by
Jun 29, 2015
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1926.417(b): Equipment and circuits.  Equipment or circuits that were deenergized were not rendered inoperative and did not have tags attached at all points where such equipment or circuits can be energized:  In the room in back of the gift shop area, there were no tags on the 20 ampere circuit breakers 8 and 20 that were in the off position and that had been used to supply power to the wires in receptacle boxes in the gift shop area.  The boxes were about 2 inches wide by 3 inches high and bottoms were about 23 inches above the floor.  The wires were removed from the breakers and wire nuts were on the wires rolled up in the receptacle boxes.  There were no covers or receptacles on the boxes.  Harrah's Resort electrical maintenance staff had access to the panel and can reattach wires to the breakers in the panel.  The door to the room and the door on the panel were not locked.  W.E. O'Neil, the general contractor onsite, hired Anderson Howard Electric, Inc., to do the electrical installation work onsite.  Anderson Howard Electric had locks on the breakers when they performed work on the equipment, and removed the locks when they finished their work onsite.  W.E. O'Neil, the controlling contractor, did not ensure the breakers were locked out or tagged after Anderson Howard Electric left the project.  Pfinish Koncepts dba Stone Craft employees, laying out the floor installation and using rollers attached to poles and sponges to apply sealant on the floor next to the receptacle boxes, were exposed to the hazard of contacting electricity.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1785

View Pfinish Koncepts, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340669407.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.