Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PROGRESSIVE WASTE SOLUTIONS OF MO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PROGRESSIVE WASTE SOLUTIONS OF MO, INC. in 196 NORTHWEST INDUSTRIAL COURT, BRIDGETON, MO 63044 (NAICS 562111). OSHA activity number 340671460.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Progressive Waste Solutions of MO, INC. — free Get an email when a new federal OSHA severe-injury report for Progressive Waste Solutions of MO, INC. is published. One employer, no account, unsubscribe in one click.
Site address
196 NORTHWEST INDUSTRIAL COURT
City
BRIDGETON
State
MO
ZIP
63044
Mailing
196 NORTHWEST INDUSTRIAL COURT, BRIDGETON, MO 63044
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562111
Employees
125
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Other-than-serious 1 instance 125 exposed
Issued
Jul 9, 2015
Abate by
Feb 16, 2016
Penalty
Initial $5,000 · Current $5,000
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards in that compressed gas container storage areas were not prominently posted with the hazard class or the name of the gases stored.  Compressed Gas Association Standard P-1, 2008, Para 5.8.1:  "Container storage areas shall be prominently posted with the hazard class or the name of the gases stored."    On the north side of the maintenance shop, acetylene and oxygen were stored next to the exterior wall with no posting as to hazard class or name of gases stored.
Recent events (3)
  • — F (O) $5000
  • — C (S) $5000
  • — Z (S) $5000

1910.37 A02

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Jul 9, 2015
Abate by
Aug 3, 2015
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.37(a)(2): Exit routes were not arranged so that employees did not have to travel toward a high hazard area:  Using the exit door at the north side of the maintenance shop, employees had to travel past acetylene storage and a 10 gallon, open container of diesel fuel.  Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos, which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (3)
  • — F (S) $0
  • — C (S) $5000
  • — Z (S) $5000

1910.147 C06 I

Other-than-serious 1 instance 4 exposed
Issued
Jul 9, 2015
Abate by
Feb 16, 2016
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:      A periodic inspection of the energy control procedure was not conducted at least annually, which included such inspection being performed by an authorized employee other than the ones(s) utilizing the energy control procedure being inspected, and a certification that the periodic inspection had been done.
Recent events (3)
  • — F (O) $5000
  • — C (S) $5000
  • — Z (S) $5000

1910.253 B04 III

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Jul 9, 2015
Abate by
Jul 24, 2015
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:   On the northwest side of the maintenance shop next to the oxygen storage was an oil cart placed within three feet of the oxygen storage.  Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos, which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (3)
  • — F (S) $0
  • — C (S) $5000
  • — Z (S) $5000

1910.303 G02 II

Other-than-serious 1 instance 10 exposed
Issued
Jul 9, 2015
Abate by
Dec 30, 2015
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.303(g)(2)(ii):  In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:    At the north side of the maintenance shop next to the oxygen storage, an electrical outlet with a metal container pushed against it was damaged.       Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos, which you believe will be helpful.  The abatement certification sheet is enclosed with the citation(s).
Recent events (3)
  • — F (O) $5000
  • — C (S) $5000
  • — Z (S) $5000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340671460.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.