Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALITY TENCHING & PLUMBING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of QUALITY TENCHING & PLUMBING in 935 AMELIA STREET, BELLE VERNON, PA 15012 (NAICS 238910). OSHA activity number 340675818.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Tenching & Plumbing — free Get an email when a new federal OSHA severe-injury report for Quality Tenching & Plumbing is published. One employer, no account, unsubscribe in one click.
Site address
935 AMELIA STREET
City
BELLE VERNON
State
PA
ZIP
15012
Mailing
214 OLIVE STREET P.O. BOX 390, HUNKER, PA 15639
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
1
Ownership type
A

4 citations on file for this inspection.

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 5, 2015
Abate by
Jun 11, 2015
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:       a) 935 Amelia Street, Belle Vernon, PA 15012:  Observed on or about June 03, 2015, the spoil pile from a trench was not placed at least 2 feet from the edge of the trench.  An employee working at the bottom of the trench was exposed to struck-by and engulfment hazards while installing a 4 inch diameter sewer line at the bottom of the trench.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 5, 2015
Penalty
Initial $2,800 · Current $1,944 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:    a) 935 Amelia Street, Belle Vernon, PA 15012:  Observed on or about June 03, 2015, an employee working at the bottom of a trench that was approximately 9 feet deep with near vertical sidewalls was not protected from cave-ins.  The employee was exposed to an engulfment hazard while installing a 4 inch diameter sewer line located at the bottom of the trench.
Recent events (2)
  • — I (S) $1944
  • — Z (S) $2800

1926.651 K02

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions had been taken to ensure their safety:       a) 935 Amelia Street, Belle Vernon, PA 15012:  Observed on or about June 03, 2015, the competent person did not remove an employee from a trench that was approximately 9 feet in depth with near vertical sidewalls when hazardous conditions existed.  The employee was not protected from cave-ins, the spoil pile was not set back at least two feet from the edge of the trench, and a ladder used as a means of egress was not long enough to reach over the tope of the trench by at least three feet.  The employee was exposed to struck-by, fall, and engulfment hazards while installing a 4 inch diameter sewer line located at the bottom of the trench.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 5, 2015
Abate by
Jun 11, 2015
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a) 935 Amelia Street, Belle Vernon, PA 15012:  Observed on or about June 03, 2015, a portable ladder used as a means of access/egress in a 9 foot deep trench did not extend at least 3 feet above the top of the trench.  The employee using the ladder as a means of trench access/egress was exposed to a fall hazard of approximately 9 feet to the bottom of the trench.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340675818.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.