OSHA Inspection: U.S. FOREST SERVICE WIND RIVER RANGER STATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of U.S. FOREST SERVICE WIND RIVER RANGER STATION in 1262 HEMLOCK RD., CARSON, WA 98610 (NAICS 115310). OSHA activity number 340677814.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Forest Service Wind River Ranger Station — free Get an email when a new federal OSHA severe-injury report for U.S. Forest Service Wind River Ranger Station is published. One employer, no account, unsubscribe in one click.
Site address
1262 HEMLOCK RD.
City
CARSON
State
WA
ZIP
98610
Mailing
10600 NE 51ST CIRCLE, VANCOUVER, WA 98682
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
115310
Employees
16
Ownership type
D

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:  A)     In the shop, there was a chop saw that had its lower blade guard locked in the up position exposing the employee to the saw blade when they raised the arm.  B)      In the shop there was a horizontal band saw that did not have an adjustable guard covering the exposed portions of the blade.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Serious Gravity 1 1 instance 7 exposed
Issued
Sep 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  A)     In the fire Cache, There was a fire extinguisher that was not mounted on h wall, and was placed on the floor.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340677814.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.