READING, PA —
OSHA Inspection: G & H CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of G & H CONSTRUCTION in 2204 GRING DRIVE, READING, PA 19610 (NAICS 238160). OSHA activity number 340680123.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G & H CONSTRUCTION
- Site address
- 2204 GRING DRIVE
- City
- READING
- State
- PA
- ZIP
- 19610
- Mailing
- 244 WEST MAIN STREET SUITE C, MOORESTOWN, NJ 08057
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 G01 VII
- Issued
- Jul 23, 2015
- Abate by
- Aug 11, 2015
- Penalty
- Initial $7,000 · Current $4,410 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) 2204 Gring Drive, Reading, PA; Employees were removing facia and installing siding while working on pump jack scaffolding at heights between 12 feet 7 inches and 16 feet 10 inches above the ground without the use of fall protection, on or about 06/04/2015. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (W) $4410
- — Z (W) $7000
1926.501 B13
- Issued
- Jul 23, 2015
- Abate by
- Aug 11, 2015
- Penalty
- Initial $7,000 · Current $4,410 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 2204 Gring Drive, Reading, PA; Employees were removing facia and installing siding at heights between 8 feet 9 inches and 15 feet 5 inches above the ground without the use of fall protection, on or about 06/04/2015. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (W) $4410
- — Z (W) $7000
1926.1053 B01
- Issued
- Jul 23, 2015
- Abate by
- Aug 11, 2015
- Penalty
- Initial $7,000 · Current $4,410 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 2204 Gring Drive, Reading, PA; Employees used a Keller 24 Foot Extension Ladder that was not 3 feet above the landing to access the roof work area, on or about 06/04/2015. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (W) $4410
- — Z (W) $7000
More inspections at G & H Construction
View G & H Construction's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340680123.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.