Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: DANNY QUEEN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DANNY QUEEN in 3169 LIFER LANE, LANCASTER, OH 43130 (NAICS 238130). OSHA activity number 340680719.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Danny Queen for free Get an email when a new federal OSHA severe-injury report for Danny Queen is published. One employer, no account, unsubscribe in one click.
Establishment
DANNY QUEEN
Site address
3169 LIFER LANE
City
LANCASTER
State
OH
ZIP
43130
Mailing
8717 RICHHOLLOW ROAD, LANCASTER, OH 43130
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
Private (A)

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 22, 2015
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents.  a. An employee was observed using a nail gun to secure decking without eye protection, thereby being exposed to a struck by flying object hazard.
Recent events (2)
  • · I (S) $1190
  • · Z (S) $1700

1926.405 A02 II I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 22, 2015
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage.  a. The flexible cord for the circular saw was cut down into the copper and then taped up with electrical tape, thereby exposing employees to an electrical hazard.
Recent events (2)
  • · I (S) $1190
  • · Z (S) $1700

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 22, 2015
Abate by
Aug 11, 2015
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a. An employee was observed on the roof without fall protection. The employee was exposed to a fall hazard of 9 feet.
Recent events (2)
  • · I (S) $1190
  • · Z (S) $1700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340680719.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.