OSHA Inspection: L C UNITED PAINTING CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of L C UNITED PAINTING CO. in 405 MINE ROAD, BARABOO, WI 53913 (NAICS 238320). OSHA activity number 340682392.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch L C United Painting CO. — free Get an email when a new federal OSHA severe-injury report for L C United Painting CO. is published. One employer, no account, unsubscribe in one click.
Site address
405 MINE ROAD
City
BARABOO
State
WI
ZIP
53913
Mailing
3525 BARBARA DRIVE, STERLING HEIGHTS, MI 48310
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
15
Ownership type
A

25 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 2 instances 4 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to fall hazards:     a)  Wire rope used to rig the ladders inside the bowl were exposed to sharp edges where the wire rope passed through holes cut in the steel near the top of the bowl.     Among other methods, one feasible and acceptable abatement method to correct this hazard is to pad or protect any sharp corners the sling is in contact with.    ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d). 29 CFR 1926.251(c)(5)(i): The U section of U-bolt wire rope clip(s) used to form eyes was not in contact with the dead end of the rope:      In rigging the containment the employer had 19 U-bolt wire rope clip eyes that were not in contact with the dead end of the rope.         ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(C).
Recent events (3)
  • — F (S) $3230
  • — C (S) $5390
  • — Z (S) $5390

1926.302 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $3,230 Reduced
29 CFR 1926.302(b)(1): Pneumatic power tool(s) were not secured to the hose or whip by some positive means to prevent the tool from becoming accidentally disconnected:    On or about June 2, 2015, pneumatic power tools were used in the bowl section of the water tower and were not secured to the hose or whipped by some positive means to prevent the tool from becoming accidentally disconnected.     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $3230
  • — C (S) $5390
  • — Z (S) $5390

1926.351 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $3,850 · Current $3,230 Reduced
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair:    Employees were using welding leads that were damaged exposing them to electrical hazards, such as but not limited to, electrical shock.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(c).
Recent events (3)
  • — F (S) $3230
  • — C (S) $3850
  • — Z (S) $3850

1926.403 B01

Serious Gravity 10 3 instances 2 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $3,230 Reduced
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:    The employer was using electrical equipment that was not free from recognized hazards.     a.  On or about June 10, 2015, employees mixing paint and walking around the water tower were exposed to electrical hazards due to a damaged green extension cord that was powering the Black & Decker hand grinder.    b.  On or about June 10, 2015 employees working on top of the water tower were exposed to electrical hazards due to using a Black & Decker grinder that had a damaged electrical cord.    c.  Employees working in the paint mixing area were exposed to electrical hazards due to using a Rigid Drill that had a damaged electrical cord.     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $3230
  • — C (S) $5390
  • — Z (S) $5390

1926.404 B01 I

Serious Gravity 10 1 instance 6 exposed
Issued
Nov 30, 2015
Penalty
Initial $5,390 · Current $3,230 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.    The employer did not utilize ground fault circuit interrupters nor did they have an assured grounding program in place while using temporary wiring.
Recent events (3)
  • — F (S) $3230
  • — C (S) $5390
  • — Z (S) $5390

1926.405 A02 II I

Serious Gravity 5 1 instance 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $3,850 · Current $3,230 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage.    On or about June 10, 2015, electrical cords were running through the water tower base door and were not protected from damage.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(c).
Recent events (3)
  • — F (S) $3230
  • — C (S) $3850
  • — Z (S) $3850

1926.404 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $3,850 · Current $3,230 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    On or about June 9, 2015, a green extension cord powering the Black & Decker Hand grinder had a missing ground prong.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(c).
Recent events (3)
  • — F (S) $3230
  • — C (S) $3850
  • — Z (S) $3850

1926.501 B04 I

Serious Gravity 10 4 instances 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $3,230 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:    Employees who were climbing ladders inside the water tower were exposed to fall hazards due to unprotected holes.     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $3230
  • — C (S) $5390
  • — Z (S) $5390

1926.502 D15

Serious Gravity 10 3 instances 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $3,230 Reduced
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.    Employees who were climbing fixed ladders inside the water tower were using a rope grab system as a fall protection with an anchorage that was not capable of supporting at least 5,000 pounds.      ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $3230
  • — C (S) $5390
  • — Z (S) $5390

1926.600 A05

Serious Gravity 5 1 instance 6 exposed
Issued
Nov 30, 2015
Penalty
Initial $3,850 · Current $3,230 Reduced
29 CFR 1926.600(a)(5): Equipment cab glass introduced visible distortion that affected the safe operation of the machine.    The glass/windshield on the Sky Trak Forklift Model 842 was damaged and obstructed the operators visibility.
Recent events (3)
  • — F (S) $3230
  • — C (S) $3850
  • — Z (S) $3850

1926.602 C01 VI

Serious Gravity 5 1 instance 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 14, 2015
Penalty
Initial $3,850 · Current $3,230 Reduced
29 CFR 1926.602(c)(1)(vi): Industrial truck(s) in use did not meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute B56.1-1969, Safety Standards for Powered Industrial Trucks.    On or about June 10, 2015, the employer did not regularly inspect and maintain safe operating conditions when operating a Sky Trak Forklift Model 842 without warning devices, such as back alarms.      ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(c).
Recent events (3)
  • — F (S) $3230
  • — C (S) $3850
  • — Z (S) $3850

1926.1053 A19

Serious Gravity 10 4 instances 4 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $3,230 Reduced
29 CFR 1926.1053(a)(19): Where the total length of a climb on a fixed ladder equaled or exceeded 24 feet (7.3 m), the fixed ladder was not equipped with either:  (i) a ladder safety device;  (ii) self-retracting lifelines with rest platforms at intervals.    Employees were accessing the interior of a water tower without fall protection.     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $3230
  • — C (S) $5390
  • — Z (S) $5390

1926.451 D10

Deleted Serious Gravity 5 3 instances 4 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $3,850 · Current $0 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    Employees working inside the water tower bowl section painting and blasting were using an aluminum ladder in purpose in which it was not designed.    ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d) 29 CFR 1926.451(d)(10): Ropes were not inspected by a competent person prior to each work shift and replaced if any physical damage impairing the function and strength of the rope existed.   Employees were using single point suspension scaffolding with wire rope that was not inspected by a competent person prior to each work shift.   ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(C).
Recent events (3)
  • — F (S) $3230
  • — C (S) $5390
  • — Z (S) $5390

1926.451 F03

Deleted Serious Gravity 5 3 instances 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder:    Employees working inside the water tower bowl section painting and blasting were using an aluminum ladder at angle 90 degrees to 0 degrees.    ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d). 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    Employees were using single point suspension scaffolding that was not inspected for visible defects by a competent person prior to each work shift.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(C).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 F07

Deleted Serious Gravity 5 3 instances 5 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $3,850 · Current $0 Reduced
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards.    Employees were not trained to recognize hazards associated with ladders, such as but not limited to, proper use of a ladder.     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d) 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: Such activities were not performed only by experienced and trained employees selected for such work by the competent person.   Employees erecting, moving, dismantling, or altering single point suspension scaffolding inside the water tower were not under the direction and supervision of a competent person.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(C).
Recent events (3)
  • — F (S) $3230
  • — C (S) $5390
  • — Z (S) $5390

1926.502 D21

Deleted Serious Gravity 10 3 instances 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:   Employees working inside and outside of the water tower were using personal fall arrest systems that were not inspected prior to each use.     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(D).
Recent events (3)
  • — F (S) $0
  • — C (S) $5390
  • — Z (S) $5390

1910.178 L01 I

Other-than-serious 2 instances 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 29, 2015
Penalty
Initial $3,850 · Current $1,616 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(c).
Recent events (3)
  • — F (O) $1616
  • — C (S) $3850
  • — Z (S) $3850

1926.20 B02

Other-than-serious 1 instance 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $1,616 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person:    A competent person did not conduct frequent and regular of jobsite inspections, such as but not limited to, ladders and electrical cords.     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d).
Recent events (3)
  • — F (O) $1616
  • — C (S) $5390
  • — Z (S) $5390

1926.302 B07

Other-than-serious 1 instance 1 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $3,080 · Current $1,616 Reduced
29 CFR 1926.302(b)(7): Compressed air hose(s) exceeding 1/2 inch inside diameter, did not have a safety device at the source of supply or branch line to reduce pressure in case of hose failure.    On or about June 2, 2015, safety devices were not installed at the Ingersoll-Rand air compressor to reduce pressure in case of a hose failure.      ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(c).
Recent events (3)
  • — F (O) $1616
  • — C (S) $3080
  • — Z (S) $3080

1926.405 G02 IV

Other-than-serious 2 instances 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 9, 2015
Penalty
Initial $3,850 · Current $1,616 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws.    The employer was utilizing flexible cords that had damage due to the cords not having strain relief provided.     a.  Employees in the cone area of the tower were exposed to electrical hazards due to utilizing damage flexible cords that had no strain relief.      b.  Employees in the time clock area were exposed to electrical hazards due to utilizing damage flexible cords that had no strain relief.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(c).
Recent events (3)
  • — F (O) $1616
  • — C (S) $3850
  • — Z (S) $3850

1926.451 G03 I

Other-than-serious 2 instances 4 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $1,616 Reduced
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion.    A rope grab system used as a vertical lifeline for employees in the single point suspension scaffolding did not have an anchorage capable of supporting at least 5,000 lbs.  The rope grab was anchored to a guardrail that had sharp edges without padding and was tied in a knot.     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d).
Recent events (3)
  • — F (O) $1616
  • — C (S) $5390
  • — Z (S) $5390

1926.502 D23

Other-than-serious 3 instances 3 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(23): Personal fall arrest systems were attached to guardrail systems or to hoists:    A rope grab system used as a vertical lifeline for employees in the single point suspension scaffolding was attached to a guardrail.     ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d).
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 D16 III

Other-than-serious 1 instance 1 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $4,620 · Current $1,616 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    On or about June 16, 2015, an employee was working from the top of the shot pot and was using a personal fall arrest system that would allow him to free fall a distance greater than 6 feet.      ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(c).
Recent events (3)
  • — F (O) $1616
  • — C (S) $4620
  • — Z (S) $4620

1926.502 D20

Other-than-serious 1 instance 6 exposed
Issued
Nov 30, 2015
Abate by
Dec 8, 2015
Penalty
Initial $5,390 · Current $1,616 Reduced
29 CFR 1926.502(d)(20): The employer did not provide for prompt rescue of employees in the event of a fall or did not assure that employees were able to rescue themselves:    No rescue plan was in place in the event of a fall where employees were working on the exterior of the water tower.
Recent events (3)
  • — F (O) $1616
  • — C (S) $5390
  • — Z (S) $5390

1926.503 A01

Other-than-serious 5 instances 5 exposed
Issued
Nov 30, 2015
Abate by
Dec 14, 2015
Penalty
Initial $5,390 · Current $1,616 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    Employees working inside the water tower bowl were not trained in the recognition of fall hazards and how to minimize them.    ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM IN ACCORDANCE WITH REQUIREMENTS OF 29 CFR 1903.19(d)
Recent events (3)
  • — F (O) $1616
  • — C (S) $5390
  • — Z (S) $5390

View L C United Painting CO.'s full OSHA safety record →