Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BFI WASTE SERVICES, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BFI WASTE SERVICES, LLC. in 1405 MEREDITH PARK DRIVE, MCDONOUGH, GA 30253 (NAICS 562111). OSHA activity number 340684356.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BFI Waste Services, LLC. — free Get an email when a new federal OSHA severe-injury report for BFI Waste Services, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1405 MEREDITH PARK DRIVE
City
MCDONOUGH
State
GA
ZIP
30253
Mailing
1405 MEREDITH PARK DRIVE, MCDONOUGH, GA 30253
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562111
Employees
30000
Ownership type
A

3 citations on file for this inspection.

1910.157 C01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 24, 2015
Abate by
Jul 21, 2015
Penalty
Initial $3,740 · Current $0 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  On or about 06/3/15 located in bay # 1: The fire extinguisher was not mounted and setting on the floor.
Recent events (3)
  • — D (S) $0
  • — C (S) $3740
  • — Z (S) $3740

1910.303 G01 IV B

Other-than-serious 1 instance 3 exposed
Issued
Jun 24, 2015
Abate by
Jul 21, 2015
Penalty
Initial $3,740 · Current $500 Reduced
29 CFR 1910.303(g)(1)(iv)(B): Where the working space required by paragraph (g)(1)(i) of this section is doubled, only one entrance to the working space is required; however, the entrance shall be located so that the edge of the entrance nearest the equipment is the minimum clear distance given in Table S-1 away from such equipment.     On or about 6/3/15 located near bay # 1 in the corner: The electrical panel board # 1405 was blocked with a battery charger, portable light stand and the floor cleaner machine parked in front and with a clearance of only 16 inch.
Recent events (3)
  • — F (O) $500
  • — C (S) $3740
  • — Z (S) $3740

1910.305 G01 IV

Other-than-serious 1 instance 2 exposed
Issued
Jun 24, 2015
Abate by
Jul 21, 2015
Penalty
Initial $3,740 · Current $500 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a):     On or about 6/3/15 located in bay # 2:  The work bench had various tools plugged in to a temporary wiring Power Strips & Multi-Outlet, a flexible extension cord was used for over one year.
Recent events (3)
  • — F (O) $500
  • — C (S) $3740
  • — Z (S) $3740

View BFI Waste Services, LLC.'s full OSHA safety record →