OSHA Inspection: ACUMARK, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACUMARK, INC in 702 EXETER AVENUE, WEST PITTSTON, PA 18643 (NAICS 323120). OSHA activity number 340685957.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acumark, INC — free Get an email when a new federal OSHA severe-injury report for Acumark, INC is published. One employer, no account, unsubscribe in one click.
Establishment
ACUMARK, INC
Site address
702 EXETER AVENUE
City
WEST PITTSTON
State
PA
ZIP
18643
Mailing
702 EXETER AVENUE, WEST PITTSTON, PA 18643
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323120
Employees
8
Ownership type
A

12 citations on file for this inspection.

1910.305 B02 I

Serious Gravity 5 5 instances 3 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $2,000 · Current $1,800 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a) Shop: The cover to the electrical box on the Adast guillotine cutter was missing exposing the energized conductors to contact, as observed on or about June 16, 2015.    b) Shop: The cover to the electrical box on the Bell and Howell folder was missing exposing the energized conductors to contact, as observed on or about June 16, 2015.    c) Shop: The electrical raceway, located along the east wall, was not equipped with a cover exposing the energized conductors to contact, as observed on or about June 8, 2015.    d) Shop: An electrical junction box, located on a center column, was not equipped with a cover exposing the energized conductors to contact, as observed on or about June 8, 2015.    e) Storage room: The cover on an electrical receptacle box (#3A) was pulled away from the box exposing the energized conductors to contact, as observed on or about June 8, 2015.    Abatement Certification Required.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2000

1910.303 B07

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner:  a) Shop: Electrical conductors used to energize the guillotine cutter were not installed in conduit and presented an electrical hazard, as observed on or about June 16, 2015.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a) Shop: An unused opening in the letter shop panel (missing breaker/knockout) was not effectively closed, as observed on or about June 8, 2015.    Abatement Certification Required.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1200

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Shop: An electrical handy box was being used as part of a drop pendant assembly and was not secured, as observed on or about June 16, 2015.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $1,600 · Current $1,400 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a) Shop: Power transmission pulleys on the rear of the Bell & Howell folding machine were not guarded from contact, as observed on or about June 16, 2015.    Abatement Certification Required.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $1600

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):  a) Shop: Power transmission belts on the rear of the Bell & Howell folding machine were fully enclosed, as observed on or about June 16, 2015.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):  a) Shop: Power transmission belts (vertical) on the rear of the Bell & Howell folding machine were not guarded to prevent contact, as observed on or about June 16, 2015.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G02

Other-than-serious 1 instance 4 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    a) Shop: The employer did not provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting, on or about June 16, 2015.    Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1200

1910.157 E02

Other-than-serious 1 instance 4 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    a) Shop: Portable fire extinguishers were not visually inspected at least monthly, as observed on or about June 8, 2015.    Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.157 E03

Other-than-serious 1 instance 4 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:    a) Shop: Portable fire extinguishers were not subjected to an annual maintenance check, as observed on or about June 8, 2015.    Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.22 A01

Other-than-serious 1 instance 1 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:  a) Shop: The floor surrounding the concrete pad for the guillotine cutter was dug out an presented a trip hazard, as observed on or about June 16, 2015.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 2 exposed
Issued
Jul 10, 2015
Abate by
Aug 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Storage room: Insufficient access and working space was provided and maintained about all electrical equipment in that a table and boxes were stored in front of the electrical panel boards, as observed on or about June 8, 2015.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0