KENDRICK, ID —
OSHA Inspection: RAY DAY JR LOGGING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RAY DAY JR LOGGING, INC. in 1005 FERN HILL ROAD, KENDRICK, ID 83537 (NAICS 113310). OSHA activity number 340690270.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAY DAY JR LOGGING, INC.
- Site address
- 1005 FERN HILL ROAD
- City
- KENDRICK
- State
- ID
- ZIP
- 83537
- Mailing
- 1005 FERN HILL RD, KENDRICK, ID 83537
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 113310
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 A08 I
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $2,380 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.23(a)(8)(i): Every floor hole into which persons can accidently walk was not guarded by a standard railing with standard toe board on all exposed sides: a) Maintenance shop, second floor: On June 9, 2015 and at times prior thereto, a guardrail did not extend the entire length of the stairway opening, adjacent to the upper portion of the stairway. The unprotected floor opening created a tripping hazard at the top of the stairs. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $1250
- — Z (S) $2380
1910.184 E01
- Issued
- Jul 31, 2015
- Abate by
- Aug 26, 2015
- Penalty
- Initial $2,380 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel chain slings did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: a) Maintenance shop: On June 9, 2015 and at times prior thereto chain slings were used to lift and hold items, including but not limited to, logging machinery, while employees performed various maintenance activities on the hoisted item. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $1250
- — Z (S) $2380
1910.157 C01
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): The employer provided portable fire extinguishers that were not mounted, and located so that they were readily accessible to employees without subjecting the employees to possible injury: a) Maintenance shop: On June 9, 2015 and at times prior thereto a welding table blocked easy access to a portable fire extinguisher mounted on the wall behind it. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.244 A01 II
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(1)(ii): The rated load was not legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means: a) Portable jack stands used in the maintenance shop. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.244 A02 VI A
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(2)(vi)(a): Each jack was not thoroughly inspected for constant or intermittent use at one locality, once every 6 months: a) Maintenance shop: On June 9, 2015 and at times prior thereto an inspection program was not in place for the floor jacks that were used in various maintenance activities. Note) Certification of corrective actions IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 G05
- Issued
- Jul 31, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Maintenance shop: On June 9, 2015 and at times prior thereto the ground plug for the Jet belt sander/disc grinder was missing. b) Maintenance shop: On June 9, 2015 and at times prior thereto the ground plug for the Craftsman 8 inch bench grinder was missing. Note) Certification of corrective actions IS required for these items.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at RAY DAY JR Logging, INC.
View RAY DAY JR Logging, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 113310)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340690270.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.