PARKER FORD, PA —
OSHA Inspection: QUARRYCUT, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of QUARRYCUT, INC. in 77 WELLS ROAD, PARKER FORD, PA 19457 (NAICS 327991). OSHA activity number 340692383.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUARRYCUT, INC.
- Site address
- 77 WELLS ROAD
- City
- PARKER FORD
- State
- PA
- ZIP
- 19457
- Mailing
- 77 WELLS ROAD, PARKER FORD, PA 19457
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 20
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1000 C
- Issued
- Dec 10, 2015
- Abate by
- Jun 12, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
9010
General-duty citation text
29 CFR 1910.1000(c): An employee was exposed to respirable crystalline silica in excess of the 8-hour time weighted average limits of listed in Table Z-3: a. Rear Area, 77 Wells Road, Parkerford, PA, 19457 - On or about September 11, 2015, an employee who was using a Chop Saw to cut stone was overexposed to respirable silica dust at a concentration of 0.69 milligrams per cubic meter expressed as an 8-hour time weighted average of approximately 4.469 times the daily Permissible Exposure Limit (PEL) of 0.154 milligrams per cubic meter based on a 413 minute sampling period. The exposure calculations included a zero-increment for the 67 minutes not sampled.
Recent events (2)
- — Z (S) $2800
- — I (S) $1680
1910.1000 E
- Issued
- Dec 10, 2015
- Abate by
- Jun 12, 2016
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): a. Rear Area, 77 Wells Road, Parkerford, PA, 19457 - On or about September 11, 2015, an employee who was using a Chop Saw to cut stone was overexposed to respirable silica dust at a concentration of 0.69 milligrams per cubic meter expressed as an 8-hour time weighted average of approximately 4.469 times the daily Permissible Exposure Limit (PEL) of 0.154 milligrams per cubic meter. Feasible administrative or engineering controls to reduce exposure to respirable crystalline silica are: Isolation (e.g., control room, enclosures, or barriers). Local exhaust ventilation (LEV) systems. Substitution with non-crystalline silica material.
Recent events (2)
- — Z (S) $0
- — I (S) $0
More inspections at Quarrycut, INC.