NINNEKAH, OK —
OSHA Inspection: RIGGS ROUSTABOUT & HOTSHOT SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIGGS ROUSTABOUT & HOTSHOT SERVICES, INC. in ROSEY HAVENSTRITE 2-30H, SEC 3-6N-7W GRADY CTY, NINNEKAH, OK 73067 (NAICS 237120). OSHA activity number 340695907.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIGGS ROUSTABOUT & HOTSHOT SERVICES, INC.
- Site address
- ROSEY HAVENSTRITE 2-30H, SEC 3-6N-7W GRADY CTY
- City
- NINNEKAH
- State
- OK
- ZIP
- 73067
- Mailing
- 501 AVE J, BEAVER, OK 73932
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.21 B02
- Issued
- Jun 29, 2015
- Abate by
- Jul 22, 2015
- Penalty
- Initial $1,020 · Current $612 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: Well head area: On or about June 4, 2015, employees installing an oil/gas well's flow lines worked in a trench. The employees had not been trained on excavation hazards and their prevention. This exposed the employees to the hazard of being struck by falling soil.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1926.651 J02
- Issued
- Jun 29, 2015
- Abate by
- Jul 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: Well head area: On or about June 4, 2015, employees installing an oil/gas well's flow lines worked in a trench. The spoil bank on the north end of the trench sat on the edge of the trench walls. This exposed the employees to the hazard of being struck by falling soil.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Jun 29, 2015
- Abate by
- Jul 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when: Well head area: On or about June 4, 2015, employees installing an oil/gas well's flow lines worked in a trench. No protective system was provided for employees in the 5 feet and deeper trench . This exposed the employees to the hazard of being struck by falling soil.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 B01 I
- Issued
- Jun 29, 2015
- Abate by
- Jul 8, 2015
- Penalty
- Initial $1,360 · Current $816 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: Well area: On or about June 4, 2015, and time prior to, employees installing an oil/gas well flow lines used electric handtools powered from a truck mounted generator through a cordset. No ground fault protection was used exposing the employees to the hazard of electrical shock.
Recent events (2)
- — I (S) $816
- — Z (S) $1360
1926.416 E01
- Issued
- Jun 29, 2015
- Abate by
- Jul 1, 2015
- Penalty
- Initial $1,360 · Current $816 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: Well area: On or about June 4, 2015, and time prior to, employees installing an oil/gas well flow lines used electric handtools powered from a truck mounted generator through a cordset. The cordset was damaged and an electric handtool had a severely damaged attachment cord exposing the employees to the hazard of electrical shock.
Recent events (2)
- — I (S) $816
- — Z (S) $1360
More inspections in this industry (NAICS 237120)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340695907.