VALRICO, FL —
OSHA Inspection: FLORIDA TEN
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FLORIDA TEN in 2919 SHETLAND RIDGE DR., VALRICO, FL 33596 (NAICS 238130). OSHA activity number 340701796.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLORIDA TEN
- Site address
- 2919 SHETLAND RIDGE DR.
- City
- VALRICO
- State
- FL
- ZIP
- 33596
- Mailing
- 6633 NW 25 TERRACE, BOCA RATON, FL 33496
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jul 8, 2015
- Abate by
- Jul 20, 2015
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Employees engaged in roof decking where the roof slope was 5:12, were exposed to a fall of 10 feet to the ground, in that, no fall protection method was being used, on or about 06/11/2015.
Recent events (1)
- — Z (S) $2400
1926.1053 B01
- Issued
- Jul 8, 2015
- Abate by
- Jul 20, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; a. Employees were using a portable extension ladder to access the roof, in that, the ladder only extended 2 feet above the roof edge, on or about 06/11/2015.
Recent events (1)