Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALL & ALL CONSTRUCTION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ALL & ALL CONSTRUCTION in 20967 U.S. 19 N, CLEARWATER, FL 33765 (NAICS 236220). OSHA activity number 340704774.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL & ALL Construction — free Get an email when a new federal OSHA severe-injury report for ALL & ALL Construction is published. One employer, no account, unsubscribe in one click.
Site address
20967 U.S. 19 N
City
CLEARWATER
State
FL
ZIP
33765
Mailing
2922 W. CLIFTON STREET, TAMPA, FL 33614
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.502 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 23, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:   ((a) At the site the employee, painting the building, was exposed to a 17' fall hazard while connected to the AC unit on the roof by a rope. The connectors at the AC unit and the D Ring of the employee's harness were connected by knots tied in the rope, while working on a ladder scaffold on 6/11/2015.
Recent events (1)
  • — Z (S) $1600

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Sep 23, 2015
Abate by
Oct 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a)There was no hazard communication program that ensured employees received effective information and training on hazardous chemicals used in their work such as A-100 Acrylic Formula paint, on or about  6/11/2015.
Recent events (1)
  • — Z (O) $0

1926.503 A01

Other-than-serious 1 instance 1 exposed
Issued
Sep 23, 2015
Abate by
Oct 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  (a) At the site employees were exposed to a 17ft. fall hazard while painting on or about  6/11/2015.
Recent events (1)
  • — Z (O) $0

1926.1053 B15

Other-than-serious 1 instance 1 exposed
Issued
Sep 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use:   (a) At the site the ladder used while painting was not inspected by a competent person for visual defects on a periodic basis. The ladder was determined to have defects such as, but not limited to: damaged safety feet with rusty  bolts exposing the employee to a 17 ft. fall hazard on or about 6/11/2015.
Recent events (1)
  • — Z (O) $0

1926.1053 B16

Other-than-serious 1 instance 1 exposed
Issued
Sep 23, 2015
Abate by
Oct 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.   (a) At the site a ladder with structural defects was not removed from service, but instead was used while painting the west section of a hotel. The ladder had defects such as, but not limited to: rusty bolts on the safety feet exposing the employee to a 17 ft. fall hazard on or about 6/11/2015.
Recent events (1)
  • — Z (O) $0

1926.1060 A01

Other-than-serious 1 instance 1 exposed
Issued
Sep 23, 2015
Abate by
Oct 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a)(1): The employer did not provide a training program for each employee using ladders as necessary, enabling each employee to recognize hazards related to ladders and the procedures to be followed to minimize these hazards.  (a) At the site two employees standing on a portable ladder used as a platform to paint the exterior of a hotel were not trained in the safe use of ladders on 6/11/2015.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340704774.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.