Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DEMAROIS BUICK-GMC TRUCK

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEMAROIS BUICK-GMC TRUCK in 3115 W BROADWAY STREET, MISSOULA, MT 59808 (NAICS 441110). OSHA activity number 340706555.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Demarois Buick-Gmc Truck — free Get an email when a new federal OSHA severe-injury report for Demarois Buick-Gmc Truck is published. One employer, no account, unsubscribe in one click.
Site address
3115 W BROADWAY STREET
City
MISSOULA
State
MT
ZIP
59808
Mailing
P.O. BOX 3539, MISSOULA, MT 59807
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
38
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Other-than-serious 1 instance 2 exposed
Issued
Dec 4, 2015
Abate by
Dec 31, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) DeMarois Buick-GMC Truck Service Area:  On June 11, 2015 and at times prior, employees were exposed to hazards such as, but not limited to struck by flying parts or pieces when using an unguarded 20 ton capacity Sunex model hydraulic press.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $2800

1910.305 B02 I

Other-than-serious 1 instance 1 exposed
Issued
Dec 4, 2015
Abate by
Dec 31, 2015
Penalty
Initial $2,100 · Current $450 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    (a) Parts area of DeMarois Buick GMC-Truck: On or about June 11, 2015 and at times prior, an employee was exposed to electrical shock hazards while using the uncovered outlet to energize a fan.
Recent events (2)
  • — I (O) $450
  • — Z (S) $2100

View Demarois Buick-Gmc Truck's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340706555.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.