BROOKLYN, NY —
OSHA Inspection: SAHIN CETINKAYA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SAHIN CETINKAYA in 350 DEGRAW ST, BROOKLYN, NY 11231 (NAICS 236116). OSHA activity number 340709658.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAHIN CETINKAYA
- Site address
- 350 DEGRAW ST
- City
- BROOKLYN
- State
- NY
- ZIP
- 11231
- Mailing
- 350 DEGRAW ST, BROOKLYN, NY 11231
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.300 B01
- Issued
- Dec 7, 2015
- Abate by
- Dec 17, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Sub cellar floor, south side: Employees used an electric powered angle grinder to install floor tiles. The angle grinder was designed to accommodate a guard for the cutting wheel, and was not equipped with such guard when in use. On or about 06/10/15. b) Cellar floor, north side: An employee used an electric powered angle grinder to do framing work. The angle grinder was designed to accommodate a guard for the cutting wheel, and was not equipped with such guard when in use. On or about 06/10/15.
Recent events (1)
- — Z (S) $2000
1926.404 B01 I
- Issued
- Dec 7, 2015
- Abate by
- Dec 17, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) Sub cellar floor, south side: Employees used an electric powered angle grinder to install floor tiles. The angle grinder was connected to an extension cord, which was routed to a nearby outlet device and was not provided with a ground fault circuit interrupter. On or about 06/10/15. b) Cellar floor, north side: Employees used an electric powered hand tools to do framing work. The tools were connected to extension cords, which were routed to a nearby outlet device and were not provided with a ground fault circuit interrupter. On or about 06/10/15.
Recent events (1)
- — Z (S) $2000
1926.405 B02
- Issued
- Dec 7, 2015
- Abate by
- Dec 17, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a) Cellar floor, north side: An energized electrical circuit breaker panel was not provided with proper cover. Its energized parts were covered with cardboard paper which does not provide insulation protection against accidental contact by employees. On or about 06/10/15.
Recent events (1)
- — Z (S) $2000
1926.405 G02 IV
- Issued
- Dec 7, 2015
- Abate by
- Dec 17, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Sub cellar floor, south side: Employees used an electric powered angle grinder to install floor tiles. The angle grinder was connected to an extension cord, which was routed to a nearby outlet device and was not provided strain relief to its plug. On or about 06/10/15. b) Cellar floor, north side: An employee used an electric powered angle grinder to do framing work. The angle grinder was connected to an extension cord, which was routed to a nearby outlet device and was not provided strain relief to its plug. On or about 06/10/15.
Recent events (1)
- — Z (S) $2000
More inspections at Sahin Cetinkaya