CONROE, TX —
OSHA Inspection: AXON ENERGY PRODUCTS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AXON ENERGY PRODUCTS in 80 N FM 3083 WEST, CONROE, TX 77303 (NAICS 333132). OSHA activity number 340710805.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AXON ENERGY PRODUCTS
- Site address
- 80 N FM 3083 WEST
- City
- CONROE
- State
- TX
- ZIP
- 77303
- Mailing
- 80 N FM 3083 WEST, CONROE, TX 77303
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333132
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 7, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: The employer does not guard all the rotating parts of machines to protect the operator and other employees in the machine area. a. This violation occurred on or about June 8, 2015, and at times prior thereto, in the Lathe Center where employees were exposed to struck-by and caught-by hazards while hand polishing parts being rotated in a Mori-Seiki brand CNC metal lathe without a functioning interlocking door guard. b. This violation occurred on or about June 12, 2015, in the Horizontal Mill Center where employees were exposed to struck-by and caught-by hazards when operating Toyoda brand CNC metal mills without using interlocking door guards. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all machines that have exposed rotating parts are guarded.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.147 C04 II B
- Issued
- Jul 7, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $27,500 · Current $13,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. The employer does not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. This violation occurred on or about June 12, 2015, and at times prior thereto, throughout the facility where employees were exposed to caught-in, struck-by, and electrical hazards while performing maintenance and servicing work on machinery without clear and specific steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. Axon Energy Products was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(ii)(B), which was contained in OSHA inspection number 1030526, citation number 1 item number 1a and was affirmed as a final order on May 19, 2015, with a final abatement date of May 30, 2015, with respect to a workplace located at 80 N FM 3083 West, Conroe, TX, 77303. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that energy control procedures clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.
Recent events (2)
- — I (R) $13750
- — Z (R) $27500
1910.147 D03
- Issued
- Jul 7, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): The employer does not ensure that all energy isolating devices that were needed to control the energy to machines or equipment are physically located and operated in such a manner as to isolate the machine or equipment from the energy sources. a. This violation occurred on or about June 12, 2015, and at times prior thereto, in the boring mill area of the facility where an employee was exposed to struck-by and caught-by hazards while bypassing a safety guard to setup a Toshiba brand CNC horizontal boring mill identified by the employer as C11 without ensuring that energy isolating devices were located and operated to isolate energy sources. b. This violation occurred on or about June 12, 2015, and at times prior thereto, in the boring mill area of the facility where an employee was exposed to struck-by and caught-by hazards while bypassing a safety guard to setup a Toshiba brand CNC horizontal boring mill identified by the employer as C12 without ensuring that energy isolating devices were located and operated to isolate energy sources. c. This violation occurred on or about June 8, 2015, and at times prior thereto, in the boring mill area of the facility where an employee was exposed to struck-by and caught-by hazards while bypassing a safety guard to setup a Toshiba brand CNC horizontal boring mill identified by the employer as C13 without ensuring that energy isolating devices were located and operated to isolate energy sources. Axon Energy Products was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 1030526, citation number 1 item number 1b and was affirmed as a final order on May 19, 2015, with a final abatement date of May 30, 2015, with respect to a workplace located at 80 N FM 3083 West, Conroe, TX, 77303. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that the requirements set in 29 CFR 1910.147 are met.
Recent events (2)
- — I (R) $0
- — Z (R) $0
More inspections at Axon Energy Products
View Axon Energy Products's full OSHA safety record →
More inspections in this industry (NAICS 333132)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340710805.