Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: CANDLE CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CANDLE CONSTRUCTION, LLC in 1920 SAN BERNARDO, LAREDO, TX 78040 (NAICS 236220). OSHA activity number 340711423.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Candle Construction, LLC for free Get an email when a new federal OSHA severe-injury report for Candle Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1920 SAN BERNARDO
City
LAREDO
State
TX
ZIP
78040
Mailing
1420 WASHINGTON AVE., LAREDO, TX 78040
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 12, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights.  At this commercial building under construction, employees were applying stucco to the exterior wall while on the second level of a supported frame scaffold not fully planked.  The working platform of the scaffold consisted of two planks, exposing the employee to a fall hazard of 13 feet to the ground below.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1926.451 E01

Other-than-serious 1 instance 5 exposed
Issued
Aug 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  At this commercial building under construction, employees were applying stucco to the building and were accessing the second level of a supported frame scaffold by jumping onto a small portable ladder below the scaffold.  Lack of access exposed employees to a fall hazard of 13.9 feet to the ground below.