CAVE SPRINGS, AR —
OSHA Inspection: DAVID'S JBC SIDING & FRAMING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAVID'S JBC SIDING & FRAMING, LLC in 1001 & 1101 CHARING CROSS, CAVE SPRINGS, AR 72718 (NAICS 238160). OSHA activity number 340713635.
Where did this inspection happen?
- Establishment
- DAVID'S JBC SIDING & FRAMING, LLC
- Site address
- 1001 & 1101 CHARING CROSS
- City
- CAVE SPRINGS
- State
- AR
- ZIP
- 72718
- Mailing
- 18315 HABBERTON RD., SPRINGDALE, AR 72764
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. Multiple employees were observed working on the roofs using pneumatic nail gun less than 2 foot away from their face without using eye or face protection, exposing employee to struck by hazards from flying debris or nail.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.501 B11
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. Employees were observed performing roofing construction on both sites without adequate fall protection. This condition exposed employee to the hazard of falls from an elevation greater than 10 feet.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1440.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. Access ladder side rails did not extend at least 3 feet above the landing surface.
Recent events (2)
- — I (S) $1440
- — Z (S) $2400
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in AR
SILOAM SPRINGS, AR—2026-07-15
CR CRAWFORD CONSTRUCTION LLC
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
BRINKLEY, AR—2026-07-14
ROGER WILKISON FARMS PARTNERSHIP
SEARCY, AR—2026-07-14
MASTER?S PLASTERING & MORE INC
LITTLE ROCK, AR—2026-07-09
NABHOLZ CONSTRUCTION CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340713635.