Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRETT/ROBINSON GULF CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRETT/ROBINSON GULF CORPORATION in 25050 CANAL ROAD, ORANGE BEACH, AL 36561 (NAICS 812332). OSHA activity number 340714245.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brett/Robinson Gulf Corporation — free Get an email when a new federal OSHA severe-injury report for Brett/Robinson Gulf Corporation is published. One employer, no account, unsubscribe in one click.
Site address
25050 CANAL ROAD
City
ORANGE BEACH
State
AL
ZIP
36561
Mailing
P.O. BOX 4009, GULF SHORES, AL 36547
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812332
Employees
700
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 16, 2015
Abate by
Aug 4, 2015
Penalty
Initial $4,250 · Current $4,250
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a)  On the processing floor:  On June 17, 2015 and at times prior to; the employer exposed his employees to potential hazardous energies in that employees were allowed to work on commercial dryers, commercial washers and folding and stacking machines that have multiple energy sources such as, but not limited to 480 VAC, Pneumatic pressure, water pressure and hot and heated elements without those employees having a written machine specific lock out procedure to ensure that those energy sources were controlled while the employees were performing maintenance or servicing the machines.
Recent events (2)
  • — I (S) $4250
  • — Z (S) $4250

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 16, 2015
Abate by
Aug 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  Brett Robinson Gulf Corporation:  On June 17, 2015 and at times prior to, the employer did not ensure that lock out / Tag out procedures were annually audited to ensure that the procedures effectively controlled all energy sources and to ensure that employees follow established procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Other-than-serious 1 instance 2 exposed
Issued
Jul 16, 2015
Abate by
Aug 4, 2015
Penalty
Initial $3,400 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  The walking aisle along the north wall:  On June 17, 2015 and at times prior to the employer allowed employees to be caught in an ingoing nip point of the stacker belts.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3400

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Jul 16, 2015
Abate by
Jul 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a)  In the Quality Office:  On June 17, 2015 and at times prior to the employer exposed his employees to electrical hazards in that the employer allowed employees to use relocatable power taps that were piggy backed to each other.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Jul 16, 2015
Abate by
Aug 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a)  Along the east wall:  On June 17, 2015 and at times prior to the employer exposed his employees to electrical hazards of 110 VAC, in that employees were allowed to work around flexible cords where fixed wiring (conduit) was required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Brett/Robinson Gulf Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340714245.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.