OSHA Inspection: AUGUSTINE P. CENTOLA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AUGUSTINE P. CENTOLA in 98 POND STREET, NORFOLK, MA 02056 (NAICS 811121). OSHA activity number 340715549.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Augustine P. Centola — free Get an email when a new federal OSHA severe-injury report for Augustine P. Centola is published. One employer, no account, unsubscribe in one click.
Site address
98 POND STREET
City
NORFOLK
State
MA
ZIP
02056
Mailing
98 POND STREET, NORFOLK, MA 02056
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
8
Ownership type
A

3 citations on file for this inspection.

1910.132 D01

Serious Gravity 1 1 instance 10 exposed
Issued
Sep 9, 2015
Abate by
Oct 29, 2015
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  98 Pond Street: The employer failed to conduct an assessment of the hazards present in an auto body repair facility in order to determine the necessary personal protective equipment.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.303 B07 IV

Serious Gravity 1 1 instance 10 exposed
Issued
Sep 9, 2015
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.  98 Pond Street:  The electrical control box and the flexible power cord for the 6000 pound capacity lift were damaged exposing the employees to live electrical parts and electrical shock.
Recent events (2)
  • — I (S) $510
  • — Z (S) $1020

1910.304 G05

Serious Gravity 1 2 instances 10 exposed
Issued
Sep 9, 2015
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  98 Pond Street:  Employees were using flexible power cords where the ground pin was missing to power hand-held portable tools exposing employees to possible electrical shock.