OSHA Inspection: BBJ RENTALS, INC. DBA BBJ LINEN

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BBJ RENTALS, INC. DBA BBJ LINEN in 7855 GROSS POINT ROAD UNIT G-6, SKOKIE, IL 60077 (NAICS 812331). OSHA activity number 340718576.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BBJ Rentals, INC. DBA BBJ Linen — free Get an email when a new federal OSHA severe-injury report for BBJ Rentals, INC. DBA BBJ Linen is published. One employer, no account, unsubscribe in one click.
Site address
7855 GROSS POINT ROAD UNIT G-6
City
SKOKIE
State
IL
ZIP
60077
Mailing
7855 GROSS POINT ROAD UNIT G-6 UNIT G-6, SKOKIE, IL 60077
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812331
Employees
278
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 9, 2015
Abate by
Dec 7, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section:   a) On or about June 16, 2015, the employer did not ensure equipment-specific energy control procedures were developed, documented, and utilized for the control of potentially hazardous energy when servicing and/or maintenance of the Super Sylon Flatwork Ironer #2, Serial #128M3134, was performed.
Recent events (1)
  • — Z (S) $7000

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 9, 2015
Abate by
Dec 7, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and the requirements of this standard are being followed:       a) A periodic inspection of the energy control procedure(s) was not performed at least annually to identify potential deficiencies and to ensure skill proficiency was maintained while utilizing the procedure(s).
Recent events (1)
  • — Z (S) $7000

1910.147 C07 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 9, 2015
Abate by
Dec 7, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a) Laundry Department - On or about June 16, 2015, the employer did not ensure employees engaging in servicing and maintenance activities, such as aligning the apron on the Super Sylon Flatwork Ironer #2, Serial #128M3134, received training at the authorized level that included the types and magnitude of the energy sources in the workplace, and the methods and means necessary for energy isolation and control.
Recent events (1)
  • — Z (S) $7000

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 9, 2015
Abate by
Dec 7, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) Laundry Department - On or about June 16, 2015, the employer did not ensure the following steps for de-energization during servicing and maintenance of the Super Sylon Flatwork Ironer #2, Serial #128M3134, were achieved:   (1) Turn off and shut down power to the machinery, (2) Physically locate and operate energy-isolating devices in such a manner as to isolate the machine or equipment from the energy source(s), (3) Affix lockout/tagout devices to each energy isolating device, (4) Verify isolation and de-energization of machinery have been accomplished prior to starting the maintenance and/or servicing work.  Employees were exposed to entanglement and amputation hazards from unexpected start-up and energizing of the Super Sylon Flatwork Ironer machinery.
Recent events (1)
  • — Z (S) $7000

View BBJ Rentals, INC. DBA BBJ Linen's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340718576.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.