DEARY, ID —
OSHA Inspection: PINE CREEK LOGGING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PINE CREEK LOGGING, LLC in 915 FIRST AVE, DEARY, ID 83823 (NAICS 113310). OSHA activity number 340722289.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PINE CREEK LOGGING, LLC
- Site address
- 915 FIRST AVE
- City
- DEARY
- State
- ID
- ZIP
- 83823
- Mailing
- P. O. BOX 129, DEARY, ID 83823
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 113310
- Employees
- 2
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.23 C01
- Issued
- Aug 7, 2015
- Abate by
- Sep 18, 2015
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder: a) Maintenance shop: On June 10, 2015 and at times prior thereto a guardrail system was not in place along the open sided floor next to the stairway. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.23 D01
- Issued
- Aug 7, 2015
- Abate by
- Sep 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails: a) Maintenance shop: On June 10, 2015 and at times prior thereto the stairway to maintenance shop office and storage area did not have a stair rail or a hand rail system in place. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 E01
- Issued
- Aug 7, 2015
- Abate by
- Sep 2, 2015
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel chain slings did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: a) Maintenance shop: On June 10, 2015 and at times prior thereto chain slings were used to lift and hold items, including but not limited to, logging equipment and parts, while employees performed various maintenance activities on the hoisted item. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.215 A04
- Issued
- Aug 7, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): On offhand grinding machines, work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest: a) Maintenance shop: On June 10, 2015 and at times prior thereto the adjustment for the work rest was not maintained on the following bench grinders; Craftsman 6 inch, Amrox 8 inch, Buffalo 6 inch and an additional 6 inch bench grinder, manufacturer unknown. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $1190
- — Z (S) $2380
1910.215 B09
- Issued
- Aug 7, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceed one-fourth inch: a) Maintenance shop: On June 10, 2015 and at times prior thereto the adjustment for the tongue guard was not maintained on the following bench grinders; Craftsman 6 inch, Amrox 8 inch, Buffalo 6 inch and an additional 6 inch bench grinder, manufacturer unknown. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.243 C01 II A
- Issued
- Aug 7, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.243(c)(1)(ii)(a): A safety guard did not cover the spindle end, nut and flange projections: a) Maintenance shop: On June 10, 2015 and at times prior thereto the side covers for the abrasive wheel were not in place on the Craftsman 6 inch bench grinder and another 6 inch bench grinder, manufacturer unknown. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 A06
- Issued
- Aug 7, 2015
- Abate by
- Sep 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(6): The user did not ensure that all nameplates and markings are in place and are maintained in a legible condition: a) Maintenance shop: On June 10, 2015 the data plate on the Mitsubishi forklift was missing. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.244 A01 II
- Issued
- Aug 7, 2015
- Abate by
- Sep 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(1)(ii): The rated load was not legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means: a) Bottle jacks used in the maintenance shop. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.253 B04 III
- Issued
- Aug 7, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) Maintenance shop: On June 10, 2015 and at times there prior thereto oxygen cylinders were stored in the same area as combustible materials. b) Maintenance shop: On June 10, 2015 and at times there prior thereto oxygen and acetylene cylinders were stored together. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 C04
- Issued
- Aug 7, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface: Maintenance shop: On June 10, 2015 and at times prior thereto an energized snap switch mounted under the welding table was missing a cover plate. Note) Certification of corrective action IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Pine Creek Logging, LLC
View Pine Creek Logging, LLC's full OSHA safety record →
More inspections in this industry (NAICS 113310)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340722289.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.