INDEPENDENCE, MO —
OSHA Inspection: TOP METAL RECYCLING
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of TOP METAL RECYCLING in 1212 W US HWY 24 #B, INDEPENDENCE, MO 64050 (NAICS 423930). OSHA activity number 340723964.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOP METAL RECYCLING
- Site address
- 1212 W US HWY 24 #B
- City
- INDEPENDENCE
- State
- MO
- ZIP
- 64050
- Mailing
- 1212 W US HWY 24 #B, INDEPENDENCE, MO 64050
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.37 B02
- Issued
- Jul 8, 2015
- Abate by
- Jul 28, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit." (a) On or about June 22, 2015, the employer failed to mark the exit from the office with a sign reading "Exit." This room has two doors. One leads outside and the other leads within the building. In the event of a fire, employees would be exposed to fire hazard.
Recent events (1)
- — Z (S) $1200
1910.151 C
- Issued
- Jul 8, 2015
- Abate by
- Jul 28, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body must be provided within the work area for immediate emergency use. (a) On or about June 22, 2015, the employer failed to provide suitable facilities in the immediate area available for quick drenching or flushing of the eyes and body. Employees were exposed to corrosive sulfuric acid in batteries, in that there were no suitable facilities in the immediate area available for quick drenching or flushing of the eyes and body.
Recent events (2)
- — Z $10000
- — Z (S) $1200
1910.178 L01 I
- Issued
- Jul 8, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer must ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). (a) On or about June 22, 2015, the employer failed to establish a training and evaluation program for employees required to operate the following fork trucks: Mitsubishi S/N AF82E90014, H100XL S/N F00A021556, H110XL S/N G005D119664, exposing employees to serious caught-in, crushing, and/or struck-by hazards.
Recent events (1)
- — Z (S) $1600
1910.303 B07 I
- Issued
- Jul 8, 2015
- Abate by
- Jul 28, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings must be closed to afford protection substantially equivalent to the wall of the equipment. (a) On or about June 22, 2015, the employer failed to close unused openings in the electrical panel next to the door on the east wall of the building. Employees were exposed to risk of fire in the event of an arc flash because the panel had four (4) uncovered openings. On or about June 22, 2015, the employer failed to close an unused knockout in the top of the electrical panel next to the door on the east wall of the building. Employees were exposed to risk of fire in the event of an arc flash due to the uncovered opening. (b) On or about June 22, 2015, the employer failed to close an unused knockout in the top of the outlet box behind the vending machine next to the office door in the interior of the building. Employees were exposed to risk of fire in the event of an arc flash due to the uncovered opening.
Recent events (1)
- — Z (S) $1600
1910.303 E01 II
- Issued
- Jul 8, 2015
- Abate by
- Jul 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Other markings giving voltage, current, wattage, or other ratings as necessary. (a) On or about June 22, 2015, the employer failed to mark the electrical panel next to the door on the east wall of the building with voltage, current, wattage, or other ratings as necessary. Employees were exposed to fire and electric shock hazards.
Recent events (1)
- — Z (S) $0
1910.305 B02 I
- Issued
- Jul 8, 2015
- Abate by
- Jul 28, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings must be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. (a) On or about June 22, 2015, the employer failed to provide an electrical outlet box in the office with a faceplate. Employees were exposed to risk of fire in the event of an arc flash due to the uncovered opening.
Recent events (1)
- — Z (S) $1200
1910.305 G01 IV A
- Issued
- Jul 8, 2015
- Abate by
- Jul 28, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure; (a) On or about June 22, 2015, the employer failed to use fixed wiring and instead used damaged flexible cords and cables as a substitute for the fixed wiring of a structure in that three extension cords were connected in succession in order to supply power to the tool bench area. Employees were exposed to risk of fire and electric shock.
Recent events (1)
- — Z (S) $1600
More inspections at TOP Metal Recycling
View TOP Metal Recycling's full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340723964.