COMBINED LOCKS, WI —
OSHA Inspection: APPLETON COATED LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of APPLETON COATED LLC in 540 PROSPECT STREET, COMBINED LOCKS, WI 54113 (NAICS 322121). OSHA activity number 340728245.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APPLETON COATED LLC
- Site address
- 540 PROSPECT STREET
- City
- COMBINED LOCKS
- State
- WI
- ZIP
- 54113
- Mailing
- 540 PROSPECT STREET, COMBINED LOCKS, WI 54113
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322121
- Employees
- 570
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Aug 14, 2015
- Abate by
- Sep 21, 2015
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 6/24/2015, Additional guarding was needed on the aisle side of #7 PM winder where an area approximately 31" x 31" was open and allowed access to exposed nip points created by the ejection cylinder. Guarding that was in place above that opening needed metal mesh repair. b) On or about 6/24/2015, The #7 PM tending side rail transfer guard gate was missing. Reel guarding was also in need of repair and expansion. c) On or about 6/24/2015, Side guards were needed on the North side of the roll splitter similar to the ones on the south side.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
1910.261 K26 I
- Issued
- Aug 14, 2015
- Abate by
- Sep 21, 2015
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.261(k)(26)(i): Nipping points on drum winder(s) and rewinder(s) on the operator's side were not guarded by a barrier guard interlocked with the drive mechanism: a) On or about 6/24/2015, #1 PM re-reeler did not have the nip point guarded to prevent employees from reaching it during thread-up. b) On or about 6/24/2015, #7 PM winder did not have the nip point guarded to prevent employees from reaching it during thread-up.
Recent events (2)
- — I (S) $4900
- — Z (S) $7000
More inspections at Appleton Coated LLC
View Appleton Coated LLC's full OSHA safety record →
More inspections in this industry (NAICS 322121)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340728245.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.