Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DANIEL DE LA CRUZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DANIEL DE LA CRUZ in AT THE INTERSECTION OF MARINA AND WATER STREET, SOUTH PADRE ISLAND, TX 78597 (NAICS 236117). OSHA activity number 340733690.

Watch Daniel DE LA Cruz — free Get an email when a new federal OSHA severe-injury report for Daniel DE LA Cruz is published. One employer, no account, unsubscribe in one click.
Establishment
DANIEL DE LA CRUZ
Site address
AT THE INTERSECTION OF MARINA AND WATER STREET
City
SOUTH PADRE ISLAND
State
TX
ZIP
78597
Mailing
5800 PADRE BLVD., SOUTH PADRE ISLAND, TX 78597
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236117
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   At this workplace, employees engaged in roof decking material installation operations at the height of greater than twelve feet did not have a fall protection system in place.
Recent events (1)
  • — Z (S) $1600

1926.701 B

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement:  At this workplace, employees engaged in framing operations of a residential structure worked where reinforcing steel protruded from the floor and was not guarded.
Recent events (1)
  • — Z (S) $1600

1926.405 G02 III

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used:   At this workplace, employees conducted residential framing operations, utilized a flex cord with a repaired splice insulated by electrical tape to supply power to electrical hand tools, and did not maintain the outer sheath properties.