SOUTH PADRE ISLAND, TX —
OSHA Inspection: DANIEL DE LA CRUZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DANIEL DE LA CRUZ in AT THE INTERSECTION OF MARINA AND WATER STREET, SOUTH PADRE ISLAND, TX 78597 (NAICS 236117). OSHA activity number 340733690.
Where did this inspection happen?
- Establishment
- DANIEL DE LA CRUZ
- Site address
- AT THE INTERSECTION OF MARINA AND WATER STREET
- City
- SOUTH PADRE ISLAND
- State
- TX
- ZIP
- 78597
- Mailing
- 5800 PADRE BLVD., SOUTH PADRE ISLAND, TX 78597
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236117
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: At this workplace, employees engaged in roof decking material installation operations at the height of greater than twelve feet did not have a fall protection system in place.
Recent events (1)
- — Z (S) $1600
1926.701 B
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: At this workplace, employees engaged in framing operations of a residential structure worked where reinforcing steel protruded from the floor and was not guarded.
Recent events (1)
- — Z (S) $1600
1926.405 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: At this workplace, employees conducted residential framing operations, utilized a flex cord with a repaired splice insulated by electrical tape to supply power to electrical hand tools, and did not maintain the outer sheath properties.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 236117)
DOWNINGTOWN, PA—2026-07-09
NVR, INC.
WINSTON SALEM, NC—2026-07-08
161508 - CLAYTON PROPERTIES GROUP, INC.
PUNTA GORDA, FL—2026-07-08
SAGE HOMES LLC
LAKE STEVENS, WA—2026-07-02
WA317991942 - SEKISUI HOUSE WASHINGTON INC
HOMER GLEN, IL—2026-07-01
BEECHEN & DILL HOMES
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340733690.