On , OSHA opened a referral safety inspection of COSTAR MIDSTREAM, LLC in 3407 CAMP SWITCH ROAD, LONGVIEW, TX 75604 (NAICS 211112). OSHA activity number 340733856.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Costar Midstream, LLC — free Get an email when a new federal OSHA severe-injury report for Costar Midstream, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3407 CAMP SWITCH ROAD
City
LONGVIEW
State
TX
ZIP
75604
Mailing
1400 16TH STREET, SUITE 310, DENVER, CO 80202
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
211112
Employees
41
Ownership type
A

12 citations on file for this inspection.

1910.23 A02

Serious Gravity 10 4 instances 23 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $6,300 · Current $1,450 Reduced
29 CFR 1910.23(a)(2): Every ladderway floor opening or platform was not guarded by a standard railing with standard toeboard on all exposed sides (except at entrance to opening), with the passage through the railing either provided with a swinging gate or so offset that a person could not walk directly into the opening:    a) At the Gas-Well Gas Cryogenic Skid, employees, who climbed the south fixed ladder to access valves and check the sight-glass, were exposed to the hazard of falling more than 11-feet to the lower level.  The passage through the railing around the ladder platform was not provided with a swing gate nor was it off set so that an employee could not walk directly into the opening.    b) At the Gas-Well Gas Cryogenic Skid, employees, who climbed the north fixed ladder to access the valve to isolate the cold box side from the dehy side, were exposed to the hazard of falling more than 13-feet to the lower level. The passage through the railing around the ladder platform was not provided with a swing gate nor was it off set so that an employee could not walk directly into the opening.    c) At the Raw Product Surge Tank South, employees, who climbed the fixed ladder to access valves, were exposed to the hazard of falling more than 14-feet to the lower level. The passage through the railing around the ladder platform was not provided with a swing gate nor was it off set so that an employee could not walk directly into the opening.    d) At the Raw Product Surge Tank North, employees, who climbed the fixed ladder to access valves, were exposed to the hazard of falling more than 14-feet to the lower level. The passage through the railing around the ladder platform was not provided with a swing gate nor was it off set so that an employee could not walk directly into the opening.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $6300

1910.23 C01

Serious Gravity 10 4 instances 23 exposed
Issued
Aug 24, 2015
Abate by
Sep 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there was entrance to a ramp, stairway, or fixed ladder:    a) At the Gas-Well Gas Cryogenic Skid, employees, who accessed the north elevated work platform, were exposed to the hazard of falling more than 13-feet to the lower level. The southeast corner of the platform had an opening in the guardrail system that was approximately 37 5/8-inches wide.  The attachment point for the removable chain top-rail was broken, and the removable mid-rail chain was missing.    b) At the Raw Product Surge Tank South, employees, who accessed the elevated work platform, were exposed to the hazard of falling more than 14-feet to the lower level. The northwest corner of the platform had an opening in the guardrail system of more than 36-inches wide.      c) At the Raw Product Surge Tank North, employees, who accessed the elevated work platform, were exposed to the hazard of falling more than 14-feet to the lower level. The southwest corner of the platform had an opening in the guardrail system of more than 36-inches wide.      d) At the V-210 Storage Tank, employees, who accessed the elevated work platform, were exposed to the hazard of falling more than 14-feet to the lower level. The northwest corner of the platform had an opening in the guardrail system through which an employee could pass.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 A08

Serious Gravity 10 1 instance 23 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk shall be guarded by either: (i)  A standard railing with standard toe-board on all exposed sides, or (ii) A floor hole cover of standard strength and construction:  a) At the Gas-Well Gas Cryogenic Skid, employees, who accessed the north elevated work platform, were not protected from accidentally walking into a 32 1/8-inch long by 22-inch wide floor hole.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.24 F

Serious Gravity 10 2 instances 5 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $6,300 · Current $1,450 Reduced
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout the flight of stairs including any foundation structure used as one or more treads of the stairs:      a) On the south side of Unit 41, the fixed industrial stairs had five (5) different rise heights ranging between 7 7/8-inches and 11 1/2-inches, which exposed employees to the hazard of falling to the lower level.    b) On the north side of Unit 41, the fixed industrial stairs had five (5) different rise heights ranging between 8 1/4-inches and 10 1/8-inches, which exposed employees to the hazard of falling to the lower level.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $6300

1910.24 H

Serious Gravity 10 2 instances 5 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:   a) On the south side of Unit 41, standard railings were not provided on the open sides of the fixed industrial stairway and stair platform, which exposed employees to the hazard of falling to the lower level.  b) On the north side of Unit 41, standard railings were not provided on the open sides of the fixed industrial stairway and stair platform, which exposed employees to the hazard of falling to the lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.27 C06

Serious Gravity 5 1 instance 23 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $4,500 · Current $1,450 Reduced
29 CFR 1910.27(c)(6): The step-across distance from the nearest edge of ladder to the nearest edge of equipment or structure was more than 12 inches:    a) At the Gas-Well Gas Cryogenic Skid, employees, who climbed the north fixed ladder to access the valve to isolate the cold box side from the dehy side, were exposed to the hazard of falling more than 13-feet to the lower level.  The step-across distance from the nearest edge of ladder to the nearest edge of elevated work platform was more than 13-inches.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $4500

1910.27 D02 III

Serious Gravity 5 1 instance 23 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.27(d)(2)(iii): One rung of any section of ladder was not located at the level of the landing laterally served by the ladder:  a) At the Gas-Well Gas Cryogenic Skid, employees, who climbed the south fixed ladder to access valves and check the sight-glass, were exposed to the hazard of falling more than 11-feet to the lower level.  The top rung of the fixed ladder employees used to access the landing platform was approximately 7 1/4-inches below the platform.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Other-than-serious 1 instance 26 exposed
Issued
Aug 24, 2015
Abate by
Sep 1, 2015
Penalty
Initial $6,300 · Current $0 Reduced

Hazardous substances 1480

29 CFR 1910.151(c): Where the eyes or body of any person could be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) In the "amine" area of the gas plant, at least one (1) emergency shower and eyewash station was inoperative exposing employees to eye injuries in the event of a hydrogen sulfide exposure.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6300

1910.219 D01

Serious Gravity 5 5 instances 5 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $4,500 · Current $1,450 Reduced
29 CFR 1910.219(d)(1): Pulleys, any parts of which were seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in 29 CFR 1910.219 paragraphs (m) and (o):    a) At Unit 43, the pulleys between the engine and cooling fan(s), which were approximately 5-feet, 3 1/2-inches above the ground, were not guarded to protect employees from contacting the ingoing nip-points.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $4500

1910.219 E01 I

Serious Gravity 5 4 instances 5 exposed
Issued
Aug 24, 2015
Abate by
Sep 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts were seven (7) feet or less from the floor level, the guard did not extend to at least fifteen (15) inches above the belt or to a standard height:    a) At Unit 43, the belts between the engine and cooling fan(s), which were approximately 5-feet, 3 1/2-inches above the ground, were not guarded to protect employees from contacting the ingoing nip-points.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 25 exposed
Issued
Aug 24, 2015
Abate by
Sep 1, 2015
Penalty
Initial $4,500 · Current $1,450 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a) Along the north exterior wall of the welding shop, at least three (3) oxygen cylinders were stored next to two (2) acetylene (fuel-gas) cylinders exposing employees to fire and explosion hazards.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $4500

1910.303 F01

Serious Gravity 5 1 instance 25 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $4,500 · Current $1,450 Reduced
29 CFR 1910.303(f)(1): When each disconnecting means required by Subpart S for motors and appliances was not located and arranged so the purpose was evident, it was not legibly marked to indicate its purpose:    a) On the South wall of the engine room, the breakers in the class 1, division 1 panelboard, which were the disconnecting means to the C28 and C36 compressors and the C28 pre-lube, were not legibly marked to indicate their purpose.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $4500