Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUMMIT VACATION AND RV RESORT LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SUMMIT VACATION AND RV RESORT LLC in 13105 RIVER ROAD, NEW BRAUNFELS, TX 78132 (NAICS 721211). OSHA activity number 340741438.

Watch Summit Vacation AND RV Resort LLC — free Get an email when a new federal OSHA severe-injury report for Summit Vacation AND RV Resort LLC is published. One employer, no account, unsubscribe in one click.
Site address
13105 RIVER ROAD
City
NEW BRAUNFELS
State
TX
ZIP
78132
Mailing
13105 RIVER ROAD, NEW BRAUNFELS, TX 78132
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721211
Employees
25
Ownership type
A

5 citations on file for this inspection.

1910.305 A02 IX

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $612.00 Reduced
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard.  On 29 June 2015, and at times prior thereto, fluorescent lights within the bathroom did not have protective covers for the bulbs.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.305 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions.  On 29 June 2015, within the Reception area, Romex electrical cable entered a knockout box without protective clamps or other means to prevent abrasion, exposing employees to potential electric shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.  On 29 June 2015, duplex electrical outlet in the Office area was not protected with a cover or faceplate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  On 29 June 2015, a power strip (RPT) was installed permanently to the wall in the Reception area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1020 E02 I A

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.1020(e)(2)(i)(A): The employer did not, upon request, ensure each employee and designated representative access to employee exposure records, as relevant to employee exposure:  On or about 29 June 2015, and at times prior thereto, the employer did not provide access to exposure monitoring records regarding indoor air quality when requested by an employee. The record indicated some mold levels inside the building were greater than the outside mold levels.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340741438.