Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRED GELLER ELECTRICAL, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of FRED GELLER ELECTRICAL, INC. in 124-02 ROOSEVELT AVENUE, FLUSHING, NY 11368 (NAICS 238210). OSHA activity number 340742485.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fred Geller Electrical, INC. — free Get an email when a new federal OSHA severe-injury report for Fred Geller Electrical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
124-02 ROOSEVELT AVENUE
City
FLUSHING
State
NY
ZIP
11368
Mailing
54-15 38TH AVENUE, WOODSIDE, NY 11377
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.502 D15

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 2, 2015
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not independent of any anchorage being used to support or suspend platforms and/or were not capable of supporting at least 5,000 pounds (22.2 kN) per employee:     (a) On the Northeast Catwalk - Employee working on A-Frame Ladder 75 feet above the stands was tied off to a piece of kindorf suspended by threaded rod; on or about 06/24/2015.       NOTE:   IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1926.503 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 2, 2015
Abate by
Jul 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   (a) On the Northeast Catwalk - Employee working on A-Frame Ladder 75 feet above the stands was tied off to a piece a kindorf suspended by threaded rod.  The piece of kindorf was not structural anchorage point.; on or about 06/24/2015.      NOTE:   IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Fred Geller Electrical, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340742485.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.