PHILADELPHIA, PA —
OSHA Inspection: CLEAN HARBORS CATALYST SERVICES, LLC
Federal Agency inspection · Health discipline
At a glance
On , OSHA opened a federal Agency health inspection of CLEAN HARBORS CATALYST SERVICES, LLC in PHILADELPHIA GAS WORKS, RICHMOND PLANT 3100 EAST VENANGO STREET, PHILADELPHIA, PA 19134 (NAICS 562211). OSHA activity number 340743780.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLEAN HARBORS CATALYST SERVICES, LLC
- Site address
- PHILADELPHIA GAS WORKS, RICHMOND PLANT 3100 EAST VENANGO STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19134
- Mailing
- 802 SEACO COURT, DEER PARK, TX 77536
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562211
- Employees
- 8
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to struck by hazards created by sudden pressure buildup inside the vacuum system of the Federal Signal Vactor Guzzler XCR truck: a) PGW Port Richmond, Philadelphia, PA: On June 23, 2015, while spent Molsiv LNG-5 was being vacuumed from Vessel C-160A, two metal caps located on the silencer of the Federal Signal Vactor Guzzler XCR Vacuum Truck were ejected as the result of an unexpected accumulation of hydrocarbons in the hopper that caused a combustion event. Among other methods, one feasible and acceptable means to abate these conditions is to ensure the vessel is properly purged pursuant to the Molsiv manufacturer's guidance. abatement method to correct these hazards is to follow the truck manufacturers vacuuming procedures.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
More inspections in this industry (NAICS 562211)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340743780.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.