Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STERLING BUILDERS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STERLING BUILDERS LLC in 12 MORRIS RD, TENAFLY, NJ 07670 (NAICS 236118). OSHA activity number 340743822.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sterling Builders LLC — free Get an email when a new federal OSHA severe-injury report for Sterling Builders LLC is published. One employer, no account, unsubscribe in one click.
Site address
12 MORRIS RD
City
TENAFLY
State
NJ
ZIP
07670
Mailing
149 COLUMBUS DR., TENAFLY, NJ 07670
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
2
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 27, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   a) Exterior of Building - Front: Employee without any head protection was exposed to struck by hazards while engaged in roofing activities below another employee, on or about 6/6/2015.
Recent events (1)
  • — Z (S) $1200

1926.403 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 27, 2015
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:   a) Exterior of Building - Side Right: Employee was exposed to electric shock while utilizing a metal junction box and receptacle that were not rated for outside use to energize a compressor, on or about 6/6/15.
Recent events (1)
  • — Z (S) $2400

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): 1926.404(b)(1)(ii): At this job site, the GP5500 Generac Generator being used to energize portable grounded power tools, was not equipped with a ground fault circuit interrupter.     a) Exterior of Building - Side Right: Employees were exposed to electric shock while utilizing a Power Back 5250W generator that did not have a mounted GFCI, on or about 6/6/15.
Recent events (1)
  • — Z (S) $0

1926.405 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:    a) Exterior of Building - Side Right: Employee was exposed to electric shock while utilizing a metal junction box with open holes as part of the energizing system of electric tools, on or about 6/6/2015.
Recent events (1)
  • — Z (S) $0

1926.405 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:    a) Exterior of Building - Side Right: Employee was exposed to electric shock while utilizing a metal junction box receptacle that did not have a faceplate to energize a compressor, on or about 6/6/15.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 27, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) Exterior of Building - Roof Left Side: Employee without any means of fall protection was exposed to fall hazards of approximately 13 feet while engaged in roofing activities, on or about 6/6/2015.
Recent events (1)
  • — Z (S) $2800

View Sterling Builders LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340743822.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.