PARKERSBURG, WV —
OSHA Inspection: R&J RECYCLING, LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of R&J RECYCLING, LLC. in 1800 GARFIELD AVE., PARKERSBURG, WV 26101 (NAICS 423930). OSHA activity number 340744457.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R&J RECYCLING, LLC.
- Site address
- 1800 GARFIELD AVE.
- City
- PARKERSBURG
- State
- WV
- ZIP
- 26101
- Mailing
- 1800 GARFIELD AVE., PARKERSBURG, WV 26101
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 16
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.253 E03 II C 3
- Issued
- Jul 24, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system: a.) R&J Recycling, LLC., Yard Area: On or about 6/30/15, the employer did not provide flashback arrestors for the burning torch used by an employee. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.253 E05 IV
- Issued
- Jul 24, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.253(e)(5)(iv): Hose connections were not clamped or otherwise securely fastened in a manner that would withstand, without leakage, twice the pressure to which they would normally be subjected in service, but in no case less than a pressure of 300 p.s.i. a.) R & J Recycling, LLC., 1800 Garfield Ave. Parkersburg, WV: On or about 6/30/15, repairs made to oxygen and fuel gas burning hoses were not pressure tested to at least 300 p.s.i. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
More inspections in this industry (NAICS 423930)