HOBOKEN, NJ —
OSHA Inspection: STEVENS INSTITUTE OF TECHNOLOGY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of STEVENS INSTITUTE OF TECHNOLOGY in CASTLE POINT ON THE HUDSON, HOBOKEN, NJ 07030 (NAICS 611310). OSHA activity number 340745793.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEVENS INSTITUTE OF TECHNOLOGY
- Site address
- CASTLE POINT ON THE HUDSON
- City
- HOBOKEN
- State
- NJ
- ZIP
- 07030
- Mailing
- 507 RIVER STREET, HOBOKEN, NJ 07030
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 611310
- Employees
- 5000
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 C01
- Issued
- Sep 30, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
9020
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Above drop ceiling, 13th Floor, Howe Building, Stevens Institute of Technology The employer failed to implement their written respiratory protection program for maintenance employees using filtering facepiece respirators when required to work above drop ceilings with surfacing material containing 40% amosite asbestos. Condition note on observed on or about 06/30/2015.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.134 E01
- Issued
- Sep 30, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Above drop ceiling, 13th Floor, Howe Building, Stevens Institute of Technology The employer failed to provide medical evaluations for maintenance employees using filtering facepiece respirators when required to work above drop ceilings with surfacing material containing 40% amosite asbestos. Condition observed on or about 06/30/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Sep 30, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Above drop ceiling, 13th Floor, Howe Building, Stevens Institute of Technology The employer failed to fit test maintenance employees using filtering facepiece respirators when required to work above drop ceilings with surfacing material containing 40% amosite asbestos. Condition noted on or about 06/30/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Sep 30, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: a) Above drop ceiling, 13th Floor, Howe Building, Stevens Institute of Technology The employer failed to ensure respirator train maintenance employees on the use, care and limitations of filtering facepiece respirators used when required to work above drop ceilings with surfacing material containing 40% amosite asbestos. Condition noted on or about 06/30/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1001 D02 I
- Issued
- Sep 30, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
9020
General-duty citation text
29 CFR 1910.1001(d)(2)(i): The employer did not perform initial monitoring of employees who were, or might reasonably be expected to be exposed to airborne concentrations at or above the 8-hour TWA and/or excursion limits: a) Above drop ceiling, 13th Floor, Howe Building, Stevens Institute of Technology The employer failed to perform initial monitoring of employees required to work above drop ceilings with surfacing material containing 40% amosite asbestos. Condition noted on or about 06/30/2015.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.1001 G03
- Issued
- Sep 30, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
9020
General-duty citation text
29 CFR 1910.1001(g)(1)(ii): The employer did not provide each employee an appropriate respirator during work operations, such as maintenance and repair activities, or other activities for which engineering and/or work practice controls are not feasible: a) Above drop ceiling, 13th Floor, Howe Building, Stevens Institute of Technology Maintenance employees used filtering facepiece respirators when required to work above drop ceilings with surfacing material containing 40% amosite asbestos. Such respirators shall not be selected for protection against asbestos fibers. Condition noted on or about 06/30/2015.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.1001 J04 I
- Issued
- Sep 30, 2015
- Abate by
- Dec 18, 2015
- Penalty
- Initial $5,000 · Current $3,000 Reduced
9020
General-duty citation text
29 CFR 1910.1001(j)(4)(i): The employer did not attach labels or post signs, required by 29 CFR 1910.1001(j)(4)(i) for previously installed ACM and/or PACM, in areas where they would clearly be noticed by employees who were likely to be exposed: a) Above drop ceiling, 13th Floor, Howe Building, Stevens Institute of Technology The employer failed to attach labels or post signs for employees required to work above drop ceilings with surfacing material containing 40% amosite asbestos. Condition noted on or about 06/30/2015.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
More inspections at Stevens Institute of Technology
View Stevens Institute of Technology's full OSHA safety record →
More inspections in this industry (NAICS 611310)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340745793.