JACKSONVILLE, FL —
OSHA Inspection: D-LUX HOMES AND DEVELOPMENT CORP
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of D-LUX HOMES AND DEVELOPMENT CORP in 101 3RD AVE, JACKSONVILLE, FL 32227 (NAICS 236118). OSHA activity number 340746072.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D-LUX HOMES AND DEVELOPMENT CORP
- Site address
- 101 3RD AVE
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32227
- Mailing
- 2363 AZTEC DRIVE WEST, JACKSONVILLE, FL 32227
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 G01
- Issued
- Jul 14, 2015
- Penalty
- Initial $2,800 · Current $500 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: A). On or about July 1, 2015 an employee of D-Lux Homes was working on a tubular welded scaffold system, two tiers high (approximately 12 feet 8 inches), and was not protected from falling to the ground below by any means of Personal Fall Protection system, or guardrails and mid rails on open sides of the scaffold.
Recent events (2)
- — I (S) $500
- — Z (S) $2800
1926.451 B01
- Issued
- Jul 14, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) A). On or about July 1, 2015, an employee of D-Lux Homes and Development Corp was completing stucco repairs to an existing structure while working on the top section of a two tier tubular welded scaffold system (measured to be 12 feet 8 inches off the ground), which was not fully planked as possible between the front uprights and the guardrail supports.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02 I
- Issued
- Jul 14, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: A). On or about July 1, 2015 an employee of D-Lux Homes and Development was completing stucco repairs to an existing structure while working on a tubular welded scaffold system. The employee had erected the scaffold system on un-even surfaces using broken sections of plaster, 2x4 wood planks, and broken sections of concrete as a mud-sill not in accordance with this section.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B04
- Issued
- Jul 14, 2015
- Penalty
- Initial $2,400 · Current $500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: A). On or about 7/1/2015, Employee was using a 6 foot aluminum A frame folding ladder set atop the top working platform of the scaffold leaning against the wall to gain access to the top of the archway roof structure. The ladder was too short to accommodate access to the archway roof top, and using it in a folded manner is not the purpose for which the ladder was designed.
Recent events (2)
- — I (S) $500
- — Z (S) $2400
1926.454 A
- Issued
- Jul 14, 2015
- Abate by
- Aug 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. A). On or About July 1,2015, Mr. Lee an employee of D-Lux Homes and Development was completing stucco repairs to an existing structure while working on a tubular welded scaffold system without any means of fall protection and was exposed to a fall in excess of 10 feet to the floor below. The scaffold was not erected on stable surfaces and not fully planked. Mr. Lee said he was not trained in the proper use of scaffolds or how to recognize the hazards associated with working on scaffolds.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 236118)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340746072.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.