STEWARTSTOWN, PA —
OSHA Inspection: LFC CONTRACTORS INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LFC CONTRACTORS INC in 90 LEE STREET, STEWARTSTOWN, PA 17363 (NAICS 238160). OSHA activity number 340749217.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LFC CONTRACTORS INC
- Site address
- 90 LEE STREET
- City
- STEWARTSTOWN
- State
- PA
- ZIP
- 17363
- Mailing
- 8107 15TH AVENUE APT # 204, HYATTSVILLE, MD 20783
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Nov 23, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock or burns, were not protected by protective helmets: a) 90 Lee Street, Stewartstown PA - Employees were not provided with head protection while operating pneumatic nail guns to attach shingles to a roof and were exposed to ricochet nails, on or about June 19, 2015. b) 90 Lee Street, Stewartstown PA - Employees working on the ground under roofing operations were not provided with head protection and were exposed to falling hand tools and roofing materials, on or about June 19, 2015. No abatement certification or documentation required.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.102 A01
- Issued
- Nov 23, 2015
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) 90 Lee Street, Stewartstown PA - Employees were not provided with eye protection while operating pneumatic nail guns to attach shingles to a roof and were exposed to ricochet nails, on or about June 19, 2015. b) 90 Lee Street, Stewartstown PA - Employees were not provided with eye protection while using a circular saw and were exposed to flying dust and debris, on or about June 19, 2015. No abatement certification or documentation required.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.501 B13
- Issued
- Nov 23, 2015
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 90 Lee Street, Stewartstown PA - Employees conducting residential roofing operations on steep roofs were not provided with fall protection and were exposed to fall hazards up to 28 feet - 11 inches to the ground below, on or about June 19, 2015. b) 90 Lee Street, Stewartstown PA - Employees conducting residential roofing operations on low slope roofs were not provided with fall protection and were exposed to fall hazards up to 15 feet - 5 inches to the ground below, on or about June 19, 2015. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.20 B01
- Issued
- Nov 23, 2015
- Abate by
- Mar 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: a) 90 Lee Street, Stewartstown PA - The employer did not initiate and maintain such programs to ensure employee safety, including a program of frequent and regular inspections made by a competent person, to ensure employees use appropriate fall protection, the safe use of ladders, and the use of personal protective equipment, on or about June 19, 2015. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.21 B02
- Issued
- Nov 23, 2015
- Abate by
- Mar 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: a) 90 Lee Street, Stewartstown PA - Employees were exposed to fall hazards and struck-by hazards while performing roofing work on a residential house. The employer failed to instruct each employee in the recognition and avoidance of unsafe condition(s) such as the use of appropriate fall protection, the safe use of ladders, and the use of personal protective equipment, on or about June 19, 2015. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Nov 23, 2015
- Abate by
- Mar 31, 2016
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension was not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab rail, was not provided to assist employees in mounting and dismounting the ladder: a) 90 Lee Street, Stewartstown PA; Sunroom - A portable Werner metal extension ladder was used to gain access to the roof and the side rails extended only 7 inches above the landing surface, the ladder was not secured at its top to a rigid support and no grasping device, such as a grab rail was provided to assist employees in mounting and dismounting the ladder, thereby exposing employees to an 8 foot fall hazard to the ground below, on or about June 19, 2015. No abatement certification or documentation required.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.1053 B05 I
- Issued
- Nov 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support): a) 90 Lee Street, Stewartstown PA; Sunroom - A portable Werner metal extension ladder used to gain access to the roof was set up at an unsafe angle, on or about June 19, 2015. The horizontal distance from the top support to the foot of the ladder exceeded one-fourth of the working length. The foot of the ladder measured 6 feet from the top support and should have measured no more than 2 feet. No abatement certification or documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at LFC Contractors INC
View LFC Contractors INC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340749217.