OSHA Inspection: ARNOLD REFRIGRATION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARNOLD REFRIGRATION, INC. in 9560 BALL ST, SAN ANTONIO, TX 78217 (NAICS 238160). OSHA activity number 340750165.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arnold Refrigration, INC. — free Get an email when a new federal OSHA severe-injury report for Arnold Refrigration, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9560 BALL ST
City
SAN ANTONIO
State
TX
ZIP
78217
Mailing
1122 N CHERRY ST, SAN ANTONIO, TX 78202
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

1 citation on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 25, 2015
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-sloped roofs with unprotected sides and edges 6 feet (1.8m) or  more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line systems and guardrail systems, warning line systems and safety net systems, or warning line systems and personal fall arrest systems, or warning line systems and safety monitoring systems:  Along the top roof of the construction building, on or about July 01, 2015 and at times prior there to employee(s) were exposed to a fall of approximately 45 feet to the ground level below while installing roof insulation panels on a 2:12 roof pitch.   IN THE ALTERNATIVE:  29 CFR 1926.501(b)(2)(i): Each employee who was constructing a leading edge 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:  Along the top roof of the construction building, on or about July 01, 2015 and at times prior there to employee(s) were exposed to a fall of approximately 45 feet to the ground level below while installing roof insulation panels on a 2:12 roof pitch.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900