EMMETT, ID —
OSHA Inspection: GEM FOREST PRODUCTS LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GEM FOREST PRODUCTS LLC in 500 W MAIN ST, EMMETT, ID 83617 (NAICS 321113). OSHA activity number 340750462.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GEM FOREST PRODUCTS LLC
- Site address
- 500 W MAIN ST
- City
- EMMETT
- State
- ID
- ZIP
- 83617
- Mailing
- PO BOX 455, EMMETT, ID 83617
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 64
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.147 C04 I
- Issued
- Aug 13, 2015
- Penalty
- Initial $4,900 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. a) Waste Conveyor Area: On or about July 1, 2015 or prior thereto: Procedures were not developed for the control of potentially hazardous energy on the MCC#5 Chipper System during employee maintenance and servicing activities. This included equipment such as the Shaker Screen, Infeed to Chipper Conveyor, Conveyor to Chip Bin, Chain off Shaker, Main Conveyor, Conveyor off Chipper, Overs Conveyor, and the Sawdust Conveyor. Electrical power to this equipment was rated at 460 Volts. This item was corrected during the inspection.
Recent events (2)
- — I (S) $3000
- — Z (S) $4900
1910.147 C05 I
- Issued
- Aug 13, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $4,900 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware was not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources. a) Waste Conveyor Area: On or about July 1, 2015 or prior thereto: Locks and other hardware necessary to isolate, secure and block machines and equipment from energy sources was not provided to employees. This included hardware for to prevent the release of hazardous energy on the MCC#5 Chipper System during employee maintenance and servicing activities. This included equipment such as the Shaker Screen, Infeed to Chipper Conveyor, Conveyor to Chip Bin, Chain off Shaker, Main Conveyor, Conveyor off Chipper, Overs Conveyor, and the Sawdust Conveyor. Electrical power to this equipment was rated at 460 Volts. Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $3000
- — Z (S) $4900
1910.147 C07 I
- Issued
- Aug 13, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees. a) On or about July 1, 2015 or prior thereto: An employee working in the waste conveyor area had not received sufficient lock-out training for activities involving the chipper system. Abatement certification and documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F
- Issued
- Aug 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f): Each disconnecting means required by this subpart for motors and appliances was not legibly marked to indicate its purpose. a) Waste Conveyor Area, on or about July 1, 2015: The disconnecting means for the MCC #5 Chipper System was not legibly marked to indicate its purpose. This item was abated during the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.265 C18 I
- Issued
- Aug 13, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $4,900 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.265(c)(18)(i): Construction, operation, and maintenance of conveyors was not in accordance with American National Standard B20.1-1957, which is incorporated by reference as specified in Sec. 1910.6. a) Waste Conveyors Area: On or about July 1, 2015 or prior thereto: The 11" wide Overs Conveyor operating at 20 FPM was damaged at the lacings, and had a portion of the conveyor belt missing that measured approximately 3" wide by 8" long. The conveyor had not been inspected periodically, and did not have worn parts replaced per Section 8 of ANSI B20.1-1957. b) Waste Conveyors Area: On or about July 1, 2015 or prior thereto: The south side of the S-Drive of the 11" wide Overs Conveyor operating at 20 FPM passed over working areas and was not guarded per Section 609 of ANSI B20.1-1957. This item was corrected during the inspection.
Recent events (2)
- — I (S) $3000
- — Z (S) $4900
1910.303 G02 I
- Issued
- Aug 13, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $3,500 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures: a) Circuit Breaker Panel, MCC #3, On or about July 1, 2015: Panel doors were open to the 480 Volt circuit breakers for the 50HP Saw, In Feed to Tom Dog, Bin Removal #2, and the Transfer to Turning Chains and Even End Roll. Abatement certification is required for this item.
Recent events (2)
- — I (S) $1800
- — Z (S) $3500
1910.333 A
- Issued
- Aug 13, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. a) Circuit Breaker Panel, MCC #3, On or about July 1, 2015: Panel doors were open to the 480 Volt circuit breakers for the 50HP Saw, In Feed to Tom Dog, Bin Removal #2, and the Transfer to Turning Chains and Even End Roll. Panel doors were open as Millwrights were accessing the panel controls to adjust the sawmill line or chain speed. Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Aug 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): The employer did not mount, locate and identify fire extinguishers so that they are readily accessible to employees without subjecting the employees to possible injury. a) Waste Conveyor Area, on or about July 1, 2015: ABC fire extinguishers were not mounted so that they are readily accessible. This item was corrected during the inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.307 F03
- Issued
- Aug 13, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(f)(3): The employer did not use dust-tight protection techniques for equipment in Class II, Division 2 and Class III locations. a) Circuit Breaker Panel, MCC #3, On or about July 1, 2015: Dust-tight protection techniques were not used for this circuit breaker panel rated at 480 Volts. Panel doors were open to the circuit breakers for the 50HP Saw, In Feed to Tom Dog, Bin Removal #2, and the Transfer to Turning Chains and Even End Roll. The panel is located in a Class III location. Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 321113)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340750462.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.