CHICAGO, IL —
OSHA Inspection: OLD VETERAN CONSTRUCTION, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of OLD VETERAN CONSTRUCTION, INC. in 4645 N SHERIDAN ROAD, CHICAGO, IL 60626 (NAICS 236220). OSHA activity number 340752088.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OLD VETERAN CONSTRUCTION, INC.
- Site address
- 4645 N SHERIDAN ROAD
- City
- CHICAGO
- State
- IL
- ZIP
- 60626
- Mailing
- 10942 S. HALSTED ST., CHICAGO, IL 60628
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 78
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 E01
- Issued
- Aug 6, 2015
- Abate by
- Sep 11, 2015
- Penalty
- Initial $3,500 · Current $2,000 Reduced
9010
General-duty citation text
29 CFR 1926.103: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter. 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On July 2, 2015, Old Veteran Construction, Inc. did not provide employees required to wear 3M 6899 Full-face respirators with P100 cartridges medical evaluations before the employees were required to use the respirator in the workplace. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2000
- — Z (S) $3500
1910.134 F02
- Issued
- Aug 6, 2015
- Abate by
- Sep 11, 2015
- Penalty
- Initial $0 · Current $0
9010P104
General-duty citation text
29 CFR 1926.103: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter. 29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) On July 2, 2015, Old Veteran Construction, Inc. did not provide employees required to wear 3M 6899 Full-face respirators with P100 cartridges with a fit test before the employees were required to use the respirator in the workplace. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H01
- Issued
- Aug 6, 2015
- Abate by
- Aug 18, 2015
- Penalty
- Initial $4,900 · Current $3,000 Reduced
9010P104
General-duty citation text
29 CFR 1926.103: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter. 29 CFR 1910.134(h)(1): Respirators were not cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer: (a) On, July 2, 2015, Old Veteran Construction, Inc. did not ensure that employees cleaned and disinfected their 3M 6899 Full-face respirators with P100 cartridges according to Appendix B of 29 CFR 1910.134. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3000
- — Z (S) $4900
1910.134 H02 I
- Issued
- Aug 6, 2015
- Abate by
- Aug 18, 2015
- Penalty
- Initial $0 · Current $0
9010P104
General-duty citation text
29 CFR 1926.103: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter. 29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (a) On July 2, 2015 Old Veteran Construction, Inc. did not ensure that respirators were stored to prevent deformation of the facepiece. Employee(s) had 3M 6899 Full-face respirator(s) with P100 cartridges that were used with a damaged facepiece. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Aug 6, 2015
- Abate by
- Sep 30, 2015
- Penalty
- Initial $3,500 · Current $0 Reduced
9010P104
General-duty citation text
29 CFR 1926.59: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.1200 of this chapter. 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Old Veteran Construction, Inc., the employer did not develop or implement a written hazard communication program in accordance with 29 CFR 1910.1200(e)(1) that would describe or include at least the following: 1) Requirement for labeling of containers of hazardous chemicals; 2) Material safety data sheet availability; 3) Training of employees; 4) A complete list of hazardous chemicals known to be in the workplace; 5) Methods to inform employees of the hazards on non-routine tasks; and 6) Methods to inform other employer(s) of material safety data sheet availability; the labeling system; and any precautionary measures to protect employees. Employees were exposed to hazardous chemicals, including silica and portland cement. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (S) $3500
1910.1200 G08
- Issued
- Aug 6, 2015
- Abate by
- Sep 30, 2015
- Penalty
- Initial $0 · Current $0
9010P104
General-duty citation text
29 CFR 1926.59: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.1200 of this chapter. 29 CFR 1910.1200(g)(8): The employer did not ensure that safety data sheets were readily accessible to the employees in their work area during each work shift: (a) On July 2, 2015, Old Veteran Construction, Inc. did not ensure that safety data sheets were readily accessible to the employees in their work area during their work shift. Safety data sheets for Spec Mix PL-04 was not kept at the jobsite for employee review. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.1126 J02 I A
- Issued
- Aug 6, 2015
- Abate by
- Sep 30, 2015
- Penalty
- Initial $3,500 · Current $0 Reduced
0689P104
General-duty citation text
29 CFR 1926.1126(j)(2)(i)(A): The employer did not provide appropriate information and training for all employees exposed to chromium (VI), in that employees could not demonstrate knowledge of the contents of the Chromium (VI) standard, 29 CFR 1926.1126: (a) On or about July 2, 2015, Old Veteran Construction, Inc. did not train employees with regard to hexavalent chromium with regard to 29 CFR 1926.1126. Spec Mix PL-04 contains between 10-30% Portland cement which contains hexavalent chromium. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (S) $3500
More inspections at OLD Veteran Construction, INC.
View OLD Veteran Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340752088.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.