ELGIN, IL —
OSHA Inspection: WEST BUILDERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WEST BUILDERS, INC. in SONORA DR. HOMESITE 112, ELGIN, IL 60124 (NAICS 238130). OSHA activity number 340755776.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WEST BUILDERS, INC.
- Site address
- SONORA DR. HOMESITE 112
- City
- ELGIN
- State
- IL
- ZIP
- 60124
- Mailing
- 303 E. MAIN ST., SAINT CHARLES, IL 60174
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Oct 5, 2015
- Penalty
- Initial $2,310 · Current $1,155 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: An employee using was using a pneumatic nail gun and did not wear safety glasses, thereby exposing the employee to the hazards associated with eye injuries. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1155
- — Z (S) $2310
1926.404 B01 I
- Issued
- Oct 5, 2015
- Penalty
- Initial $2,310 · Current $1,155 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: Employees were exposed to electrical shock hazards when using extension cords which were plugged in to a portable generator. A ground fault circuit interrupter was not used and the employer did not institute an assured equipment grounding conductor program. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1155
- — Z (S) $2310
1926.502 D16 III
- Issued
- Oct 5, 2015
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: An employee performing carpentry work from a residential roof was exposed to the hazard of free falling more than six (6) feet while using a personal fall arrest system. Rope grabs were not adjusted to protect the employee from a free fall of greater than six (6) feet. The employee was exposed to internal injuries and/or failure of personal fall arrest system. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1540
- — Z (S) $3080
1926.501 B13
- Issued
- Oct 5, 2015
- Penalty
- Initial $10,780 · Current $5,390 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Employees performing residential construction operations on the roof of a residential property, twelve (12) feet two (2) inches above the ground, were not protected from falling, thereby exposing the employees to fall hazards. West Builders, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 457453, citation number 1, item number 1 and was affirmed as a final order on July 10, 2012, with respect to a workplace located at 204 Middleton, Elgin, IL 60123. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (R) $5390
- — Z (R) $10780
More inspections at West Builders, INC.
View West Builders, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340755776.