OSHA Inspection: MARJI ELECTRIC CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARJI ELECTRIC CORP. in 230 N. BEDFORD RD., MOUNT KISCO, NY 10549 (NAICS 238210). OSHA activity number 340756758.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marji Electric Corp. — free Get an email when a new federal OSHA severe-injury report for Marji Electric Corp. is published. One employer, no account, unsubscribe in one click.
Site address
230 N. BEDFORD RD.
City
MOUNT KISCO
State
NY
ZIP
10549
Mailing
217 MOUNTAINDALE RD., YONKERS, NY 10710
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 22, 2015
Abate by
Aug 3, 2015
Penalty
Initial $1,800 · Current $1,260 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards:      location: parking lot area  on or about: 7/7/15    a) Employees were working from a truck mounted aerial lift, while installing new light fixtures. The midrail chain for the basket entrance was not engaged. The employees were not tied off using a body belt or harness. The employees were exposed to a fall of up to 15'.    Among other methods of abatement, one feasible and acceptable method to correct the hazard is to engage the midrail chain while any employee is in the basket.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $1800

1926.100 A

Serious Gravity 1 2 instances 2 exposed
Issued
Jul 22, 2015
Abate by
Aug 3, 2015
Penalty
Initial $1,080 · Current $756 Reduced
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    location: entire site  on or about: 7/7/15    a) Employees working below overhead hazards while engaged in electrical work, were not protected with hard hats.
Recent events (2)
  • — I (S) $756
  • — Z (S) $1080

1926.453 B02 V

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 22, 2015
Abate by
Aug 3, 2015
Penalty
Initial $1,800 · Current $1,260 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:     location: parking lot area  on or about: 7/7/15    a) Employees were working from a truck mounted aerial lift, while installing new light fixtures. The employees were not tied off using a body belt or harness. The employees were exposed to a fall of up to 15'.