Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUSTODIO CARPENTRY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CUSTODIO CARPENTRY, INC. in 3586 13TH STREET, NW, WASHINGTON, DC 20010 (NAICS 238130). OSHA activity number 340757756.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Custodio Carpentry, INC. — free Get an email when a new federal OSHA severe-injury report for Custodio Carpentry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3586 13TH STREET, NW
City
WASHINGTON
State
DC
ZIP
20010
Mailing
13314 KEATING STREET, ROCKVILLE, MD 20853
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
8
Ownership type
A

7 citations on file for this inspection.

1926.95 A

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2015
Penalty
Initial $1,700 · Current $1,700
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact:  a) Front Porch Roof - A laborer was observed cutting through fiber glass roof shingles with a Makita portable electric circular saw, model number 5007F, and not wearing eye protection, on or about 07/07/2015.  No abatement documentation or certification required for this item.
Recent events (1)
  • — Z (S) $1700

1926.150 C01 IV

Serious Gravity 1 1 instance 8 exposed
Issued
Sep 22, 2015
Abate by
Sep 28, 2015
Penalty
Initial $1,080 · Current $1,080
29 CFR 1926.150(c)(1)(iv): There was not at least one fire extinguisher located adjacent to stairways on each floor of a multistory building:  a) Job Site - Portable fire extinguishers were not provided anywhere in the building, on or about 07/07/2015.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $1080

1926.404 F06

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 22, 2015
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  a) First Floor Near Front Porch Roof - A laborer was using an extension cord that was missing the ground pin to supply power to a Makita portable electric circular saw used to cut existing roofing shingle, 15 amp, 120 volt service, on or about 07/07/2015.    No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $1020

1926.405 G02 IV

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a) First Floor Near Porch Roof - A laborer was using an extension cord that was showing signs of a strain to supply power to a Makita portable electric circular saw, model #5007F, used to cut existing roofing shingle, 15 amp, 120 volt service, on or about 07/07/2015.   b) Third Floor - A framing carpenter was using an extension cord that was showing signs of a strain to supply power to a DeWalt portable electric circular saw, model #DWE575, used to cut wood framing members, 15 amp, 120 volt service, on or about 07/07/2015.    No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $0

1926.416 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) First Floor Near Front Porch Roof - A laborer was using an extension cord that was frayed with an exposed conductor to supply power to a Makita portable electric circular saw used to cut existing roofing shingle, 15 amp, 120 volt service, on or about 07/07/2015.     No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $0

1926.502 D15

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2015
Penalty
Initial $1,700 · Current $1,700
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:   a) Second Floor Near Porch Roof - Two laborers were observed on the front porch roof utilizing an anchor point, as a part of the personal fall arrest system, which was not designed to accommodate attachment of two lifelines, exposing employees to a potential fall of 14 feet, on or about 07/07/15.    No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $1700

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2015
Abate by
Oct 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) Job Site - Employees were not provided with fall protection training where two employees were observed using a personal fall arrest system which had lifelines attached to the same anchor point that was rated for 5000 lbs., exposing the employees to a potential fall of 14 feet, on or about 07/07/2015.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).