Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELECTRICAL MATERIALS COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ELECTRICAL MATERIALS COMPANY in 145 ELIZABETH LANE, GENOA CITY, WI 53128 (NAICS 332999). OSHA activity number 340759208.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electrical Materials Company — free Get an email when a new federal OSHA severe-injury report for Electrical Materials Company is published. One employer, no account, unsubscribe in one click.
Site address
145 ELIZABETH LANE
City
GENOA CITY
State
WI
ZIP
53128
Mailing
145 ELIZABETH LANE, GENOA CITY, WI 53128
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
3
Ownership type
A

4 citations on file for this inspection.

1910.137 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Jan 12, 2016
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.137(c)(2)(ii): Insulating equipment was not inspected for damage before each day's use:          Rubber insulating gloves used for personnel protection during electrical testing activities were not inspected before use.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.137 C02 VIII

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Jan 5, 2016
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.137(c)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests  in accordance with Table I-5 and Table I-6:    Rubber insulating gloves used for personnel protection during electrical testing activities were not subjected to periodic electrical tests in accordance with Table I-6 in that the gloves had not been electrically tested within the past 6 months.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.335 A01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2015
Abate by
Jan 5, 2016
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed:    Employee(s) performing electrical testing on electrical circuits up to 480 volts A.C. were not provided with electrical protective equipment that was appropriate for all parts of the body to be protected, such as, but not limited to, arc-rated head and face protection, and arc-rated clothing.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.178 L01 I

Other-than-serious 1 instance 3 exposed
Issued
Dec 11, 2015
Abate by
Jan 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  The employer did not ensure that each employee whose job included the operation of forklifts had completed training and an evaluation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Electrical Materials Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340759208.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.