OSHA Inspection: B & B PALLET LUMBER LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of B & B PALLET LUMBER LLC in ROUTE 2, BOX 2447, BIRCH TREE, MO 65438 (NAICS 321113). OSHA activity number 340764760.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B & B Pallet Lumber LLC — free Get an email when a new federal OSHA severe-injury report for B & B Pallet Lumber LLC is published. One employer, no account, unsubscribe in one click.
Site address
ROUTE 2, BOX 2447
City
BIRCH TREE
State
MO
ZIP
65438
Mailing
ROUTE 2, BOX 2447, BIRCH TREE, MO 65438
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
8
Ownership type
A

2 citations on file for this inspection.

1910.219 D01

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 14, 2015
Penalty
Initial $1,020 · Current $1,020
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section.   At the time of the inspection, multiple belts and pulleys on the band saws were not covered exposing nearby workers to caught in hazards.
Recent events (1)
  • — Z (S) $1020

1910.303 G02 I

Serious Gravity 5 2 instances 8 exposed
Issued
Jul 14, 2015
Penalty
Initial $1,360 · Current $1,360
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  At the time of the inspection, the 110 volt panel and the 480 volt motor starter box did not have covers installed which exposed nearby employees to an electrical hazard.